SMB Installer Portal
Gallagher SMB
  • Welcome
  • Contacts and Systems
  • Frequently Asked Questions
  • SMB solution
    • System overview
    • Gallagher SMB hardware
    • Gallagher SMB credentials
  • Installing Gallagher SMB
    • Installer Portal overview
    • Installing the hardware
      • Pull cables
      • Installing the hardware
      • Bring Controller online
      • Voltage
      • Controller web browser configuration
      • Initialize tampers
    • Site configuration
      • Create a Site or Demo Site
      • Create a Site Template
      • Default configuration overview
      • Enable Guarding
      • Assign a controller to a site
      • Configure inputs and outputs
      • Configure readers
      • Configure monitoring
        • Alarm transmitters
        • IP Alarms
      • Configure areas
        • Configure Entry Delay
        • Configure Exit Delay
      • Configure elevators
      • Configure doors
      • Door status, history, and overrides
      • Site Actions
        • Site Details
        • Site Notes
        • Credentials
          • Credential Groups
            • FAQ
            • If no Credential Group is assigned
            • If a Credential Group is assigned
          • Edit Credentials
        • Key Account Holder
        • Display Names
        • Invite myself to the site
        • Test Mode
        • Publish/Refresh Controller configuration
    • Activation
      • Activate site
      • Onboard users
      • Installer Mode
  • Using the Gallagher SMB app
    • Gallagher SMB app overview
    • Arming and disarming
    • Access Control
      • Opening a door
      • Controlling a door remotely
      • Requesting access
      • Door states
      • Schedules
        • Door Schedules
        • User Schedules
    • Managing users
      • SMB tags (physical credentials)
      • SMB User Codes
      • Delete or disable a User
      • User Privileges
      • FIDO Authentication
    • Managing alarm incidents
      • Self monitoring
        • Respond to an incident
      • Guarding
      • Past Incidents
      • Third-party monitoring
    • Managing system alarms
    • Site activity
    • Managing multiple sites
    • Settings
  • Troubleshooting
    • Gallagher SMB Controller
    • Gallagher Hardware
    • Gallagher SMB vs Command Centre
    • Connectivity
    • Configuration
    • Credential Groups
    • SMB app
    • Notifications
    • User Management
    • Reporting an Issue
  • Release Notes
  • Disclaimer
  • Open Source Licences
Powered by GitBook
On this page

Was this helpful?

Export as PDF
  1. Using the Gallagher SMB app
  2. Managing alarm incidents

Self monitoring

PreviousManaging alarm incidentsNextRespond to an incident

Last updated 6 months ago

Was this helpful?

As a self-monitored security solution, SMB provides organisations with the ability to manage their own site's security. Site Managers will receive a notification when an alarm is triggered and then make the decision on who to respond to that incident.

There are two types of alarms that can be activated on a site:

  • Intruder Alarms

Intruder alarms

Intruder alarms are activated by sensors, such as motion detectors (PIRs) and window or door sensors (reed switches), and produce 'incidents'.

  • About incidents An incident is a real-time timeline of activity following an alarm activation. An incident shows which sensors have activated at your site, any other alarms that have occurred, and when each happened. The incident will also show any response to the incident by a Site Manager or, if you have the Guard Monitoring add-on, a Security Guard.

  • Alarms included in an incident After the first alarm, which creates the incident, any additional alarms that occur within 20 minutes of the previous one are also added to the incident. The close time frame of the alarms means that it is likely they are related.

  • Viewing an incident Alarms from the security system, the sensors and outputs, will always be displayed on the left-hand side of the incident screen. Any response to the alarm, including the person who claimed or silenced the alarm and any manual or automated guard call-outs, will display on the right-hand side of the incident screen.

  • Closing an incident An incident stays open until it has been closed by a Site Manager or after 24 hours (see ). A site could have multiple open incidents but it is unlikely. If there are multiple incidents open, only one incident (the latest one) can be in progress at any time.

System Alarms
auto-closing of incidents