Controller 6000

Understand Controller 6000 lifecycle, variants, accessories, and support status.

The Controller 6000 (C6000) is an IP based controller for localized access control, intruder alarms, perimeter security, and business automation. The range was introduced in 2009, initially with WinCE as the operating system. In late 2019, with the release of Command Centre version 8.20, the operating system migrated to Linux for improved security and performance.

Gallagher Controller 6000

🧭 Where to start

Lifecycle

Milestone
Date

C6000 standard manufacture ends

July 2026

C6000 HS manufacture ends

July 2027

C6000 family support ends

July 2031

Note: 6000 controllers now ship with Linux installed. WinCE is no longer available from factory.

Variants

Part Number
Name
Description
Supported from

C300100

Standard

The standard 6000 controller

CC 6.01

C300110

Starter Kit

Starter controller variant of the 6000 family

CC 7.30

C300111

2 Door

The 2 Door variant of the 6000 Controller family

CC 7.30

C300101

Enhanced

Enhanced variant of the 6000 controller, dual higher-network-speed

CC 7.10

C305101

High Security

High Sec variant, dual higher-network-speed, high security rating

CC 7.21

C305111

High Sec 2 Door

2 Door High Sec variant, dual higher-network-speed, high security rating

CC 8.10

⚠️ Naming change (2023): "Controller 6000 High Spec" became "Controller 6000 Enhanced" (C300101). "Controller 6000 (HS) PIV" became "High Sec Controller 6000" (C305101). See High Sec Specific Information for details.

Accessories

Part Number
Product Name
Description
Install Note

C300142 / C300182

4H Module / 8H Module

Plugs directly into a 6000 controller, allowing I/O and HBUS port expansion

3E2891 Install Note HBUS Module

C300141 / C300181

4R Module / 8R Module

Plugs directly into a 6000 controller, allowing I/O and CardaxIV or Wiegand reader connection

3E2092 Install Note Reader Module

C200620

PSTN Dialler

Allows a 6000 to be connected to a PSTN

3E5364 Install Note PSTN Dialler

Power LED removal (2025 hardware change)

In 2025 the bright Power LED is being omitted from the controller, as it is no longer a requirement. It is removed at controller serial number 2532XXXXXX onwards. This affects the 6000 Standard, Enhanced, Starter, and 2 Door variants only. SMB and High Sec continue to have them fitted.