> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/linking-devices-to-controllers.md).

# Linking devices to Controllers

The following table indicates the readers and hardware that the Controller supports:

<table><thead><tr><th width="229">Readers</th><th>Hardware</th></tr></thead><tbody><tr><td>HBUS Reader<br>HBUS Terminal<br>OSDP Reader<br>Cardax IV Reader<br>Third Party Reader<br>Morpho Biometric Reader</td><td>HBUS Alarms Only Terminal<br>HBUS F22 Fence Controller<br>HBUS 8-In 2-Out Door Module<br>HBUS 8-In Board<br>HBUS 8-In 4-Out Board<br>HBUS 16-In 16-Out Board<br>HBUS Z10 Tension Sensor Group<br>Schlage PIM<br>Aperio Door<br>Z20 Disturbance Sensor<br>D10 Taut Wire Sensor<br>Alarm Dialler</td></tr></tbody></table>

1. Click **Configure** from the menu bar, then **Hardware**.

   The **Hardware** List Window opens (in [tree view](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/list-windows/tree-view.md)).
2. Highlight the required Controller, (i.e. the one the devices are connected to).
3. **Right click** and select **Properties**.
4. Click the **Setup** tab and select the correct **RS-485 Bus** type for the RS-485 devices connected to the Controller.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-b2db0e69ef3c3a07e912ff681739b45d87801d38%2F6000_setuptab.png?alt=media)

   If the Controller has a Plug-in Module connected, select the correct Plug-in Module. Additional tabs appear in the properties when a Plug-in Module is selected.

   **Note:** When either of the RS-485 Buses or the Plug-in Module type are changed then an appropriate error message will display if there are any devices configured or detected on the bus/module that would be incompatible with the type of bus/module that is being changed.

   The **Low Power threshold** field can be altered to set the level at which a low voltage alarm will be generated for the Controller.
5. What **Plug-in Module** did you select on the **Setup** tab?

   <table><thead><tr><th width="134.66668701171875">If...</th><th>then...</th></tr></thead><tbody><tr><td>"No Module",<br>"4H Module" or<br>"8H Module"</td><td>go to Step 6.</td></tr><tr><td>"4R Module" or<br>"8R Module"</td><td>click the <strong>Readers</strong> tab.<br>Click within the edit box(es) of the reader number(s) and select the appropriate reader.<br>Go to Step 6.</td></tr></tbody></table>
6. What **RS-485 Bus** type did you select?

   <table><thead><tr><th width="134.6666259765625">If...</th><th>then...</th></tr></thead><tbody><tr><td>HBUS</td><td>refer to the topic <a href="https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/configuring-hbus-devices.md">Configuring HBUS Devices</a>.</td></tr><tr><td>Aperio</td><td>refer to the topic Assigning an Aperio Door to a Controller.</td></tr><tr><td>OSDP</td><td>refer to the topic <a href="https://help.security.gallagher.com/knowledge-hub/configuration-client/integrated-systems/open-supervised-device-protocol-osdp-integration/assigning-an-osdp-compliant-reader-to-a-gallagher-controller.md">Assigning an OSDP Compliant Reader to a Controller</a>.</td></tr><tr><td>Schlage</td><td>refer to the topic <a href="https://help.security.gallagher.com/knowledge-hub/configuration-client/integrated-systems/schlage-lock-interface/assigning-devices.md">Assigning Schlage devices to a Controller</a>.</td></tr><tr><td>Sensor</td><td>refer to the topic <a href="https://help.security.gallagher.com/knowledge-hub/configuration-client/licensable-features/perimeter-sensors/assigning-z20-and-d10-sensors-to-a-controller-6000-or-7000.md">Assigning Z20 and D10 sensors to a Controller 6000 or 7000</a>.</td></tr></tbody></table>
7. Click the **OK** button.
8. Repeat the procedure for all devices associated with this Controller.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/linking-devices-to-controllers.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.