Detection Technologies - VibraSector changes - May 2021
Review updated VibraSector cable, gate, and zone limits for perimeter estimates.
Notification
We have recently been advised of some changes in the application limits with the VibraSector Products we are distributing in the market, these changes will potentially impact on current estimates submitted to customers. These changes have been provided by Detection Technology and are as follows:
1. Total loop length (sensor + dead cable) shall not exceed 1,250m (4,100’) – refer image below for impact on return loop scenario.

2. Total Length of sensor cable shall not exceed 1,000m (3,280’).
3. Number of gate kit connection shall not exceed 4 (2x double leaf gates) per analyser.
4. Total number of zones per analyser shall not exceed 25 – currently we recommend no more than 10 to remove the need for external relay card and non-encrypted communications.
For sites that are estimated to be impacted by these limitation changes please reach out to your Gallagher representative and we will work through the impact and required changes directly with Detection Technologies