For the complete documentation index, see llms.txt. This page is also available as Markdown.

IDEMIA SIGMA fingerprint sensor firmware - May 2025

Identify affected IDEMIA SIGMA terminals and install the required firmware fix.

Essential firmware upgrade (FW 4.18.4).

As described in the IDEMIA Product Change Notification, the SIGMA Lite, Lite+ and Wide are delivered with a new fingerprint sensor, associated with Firmware 4.16, since June 2024.

IDEMIA identified that terminals with the new fingerprint sensor are not providing nominal biometric identification performance. The symptom can be a higher rejection rate for all users of the terminal. The issue was investigated and corrected in FW 4.18.4.

Impacted products

Gallagher part no.
IDEMIA part no.
Product name
Serial no.
Occurrence & action

C864180

293678615

SIGMA LITE (BIO + LED)

> SN2425

Rare occurrence. Recommended upgrade to FW 4.18.4

C864181

293678636

SIGMA LITE MULTI (BIO+CARD+LED)

> SN2425

Rare occurrence. Recommended upgrade to FW 4.18.4

C864183

293678660

SIGMA LITE+ MULTI (BIO+PIN+CARD+LCD)

> SN2425

Rare occurrence. Recommended upgrade to FW 4.18.4

C864173

293638877

SIGMA WIDE MULTI (BIO+PIN+CARD+LCD)

> SN2425

Low occurrence. Mandatory upgrade to FW 4.18.4

Factory implementation

FW 4.18.4 is implemented in IDEMIA's manufacturing for all SIGMA terminals in May 2025 (SN > 2520).

Field remediation

Download firmware 4.18.4 from biometricdevices.idemia.com and upgrade affected products.


🔗 Related

Last updated

Was this helpful?