Command Centre reports biometric mismatch error 3

Diagnose IDEMIA fingerprint recognition failures reported as “Unrecognised Biometric” in Command Centre.

Error 3 "Unrecognised Biometric" appears as a Command Centre event when the reader did not recognise the fingerprint. This is visible in the MBTB logs on the reader. Because the reader has not recognised the fingerprint, it has not sent anything to the controller.

To capture the MBTB logs, see Collect IDEMIA diagnostic logs.

Cause

A common cause is an MSO1300 enrolment 180° out: people unfamiliar with enrolling fingerprints on the MSO1300 have it 180 degrees out, so the finger is enrolled but never recognised.

Check the wiring

Confirm the Wiegand wiring by creating a tamper event. If it shows in Command Centre as an event, the wiring is correct, and the problem is the enrolment.