IDEMIA reader cannot connect after the October 2022 firmware update

Restore reader communication after the October 2022 IDEMIA firmware applies enforced security.

IDEMIA released new firmware versions on 11-10-2022. The firmware 11-10-2022 release changed the reader configuration to enforced secure.

New readers, and readers upgraded to the latest firmware, will not come online in Command Centre and cannot connect via MBTB 4.6.12 or lower. After the upgrade, the reader remains offline.

Use the On-Demand Security procedure to recover the reader. The recovery procedure, which explains how to put an IDEMIA Morpho reader into the On-demand Security state, is on Enable On-Demand Security.

A related error on v8.20 is "Invalid Binary File" or "Failed to upgrade... MBTB Version is too old", which is fixed by upgrading to the latest MBTB. See MBTB reports "Invalid Binary File" for this related MBTB version error.