MA2G and MA5G communication modes

Compare IDEMIA reader communication modes, encryption behavior, and Command Centre compatibility.

IDEMIA readers use one of two communication modes between the Command Centre server and the reader: Legacy MA2G or Native MA5G. Command Centre supports both.

  • Legacy MA2G is the older mode (MA J-Series, MA 520). VP Dual Finger Vein supports only MA2G. Not supported from 9.30.

  • Native MA5G is recommended for vEL7.80+. It is encrypted with TLS 1.2 (RSA-2048, SHA-256 certificates), and each reader has a unique certificate and key pair. Wave Compact supports only MA5G.

Legacy mode (MA2G)

Legacy mode is the older connection mode. It was traditionally used with previous reader models, for example MA J-Series and MA 520 readers.

Gallagher recommends Native mode for sites with Command Centre vEL7.80 and above, because it allows encrypted communication between the Command Centre server and the IDEMIA readers.

Encryption (Native MA5G)

Native mode lets sites use more secure TCP/IP communications for IDEMIA readers. IDEMIA readers set to Native mode (MA5G) with encryption enabled use TLS 1.2 between the Command Centre server and the reader. Encryption is RSA2048 with SHA256 hash on certificates.

Each encrypted Sigma reader is issued its own unique certificate and a unique set of public and private keys.

There are two securing methods for Morpho Sigma readers. Both are documented in "MorphoAccess Installation Guide.pdf" on the Command Centre install media:

  • Over the network via Command Centre vEL7.80 and above.

  • The Biometric Encryption Utility, a non-network solution.

Encryption defaults

  • vEL7.80 to 7.90: "Encrypt Communications" was ON by default. This caused reader lockouts for some Channel Partners when a reader was moved from a demo system to a live site without disabling encryption first. The readers became locked and unusable.

  • vEL8.00+: "Encrypt Communications" is OFF by default, with a maintenance alarm noting that the reader is unencrypted.

Connection modes by Command Centre version

Command Center Version
SIGMA Lite
SIGMA Lite Multi
SIGMA Lite +
SIGMA Lite + Multi
SIGMA BIO
SIGMA Multi
SIGMA Extreme Multi
VP BIO
Wave Compact

vEL7.30

MA2G

MA2G

MA2G

MA2G

MA2G

vEL7.40

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

vEL7.50

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

vEL7.60

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

vEL7.70

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

MA2G

vEL7.80

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

vEL7.90

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

vEL8.00

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

vEL8.10

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL8.20

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL8.30

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL8.40

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL8.50

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL8.60

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL8.70

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL8.80

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL8.90

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL9.00

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL9.10

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL9.20

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G/MA5G

MA2G

MA5G

vEL9.30

MA5G

MA5G

MA5G

MA5G

MA5G

MA5G

MA5G

not supported

MA5G

This grid uses the model names SIGMA BIO, SIGMA Multi and VP BIO, which the reader support grid on IDEMIA reader compatibility and specifications does not use. Both are shown as the source gives them.

New readers ship locked to secure communication. For security-by-default readers, see Enable On-Demand Security, which explains how to put a Morpho reader into the On-demand Security state. For the related encrypted OSDP option, see Configure IDEMIA readers over OSDP.