Wire IDEMIA readers over Wiegand
Connect IDEMIA (Morpho) readers to Gallagher controllers using Wiegand and suitable power.
Wiring Sigma readers is relatively straightforward.
Wiring (Wiegand)
Power 12V (both + and 0V). Both positive and 0 volts must be connected.
Data: D0, D1, and Wiegand ground to the Controller. These carry the data the Controller uses to identify the fingerprint. Also wire Out 1 and Out 2 so the controller sends Access Granted and Denied to the reader.

Wiring videos
Engineering-produced wiring videos are available on YouTube. The Gallagher Engineering team produced these four videos for Sigma readers, and they are publicly accessible:
C6000 + 8R/4R Module (C300100): IDEMIA (Morpho) Wiring, Controller 6000 with 8R or 4R Module.
FT GBUS URI (C200660): IDEMIA (Morpho) Wiring, FT GBUS Universal Reader Interface.
GBUS URM Wiegand (C200665): IDEMIA (Morpho) Wiring, GBUS Universal Read Module, Wiegand Variant.
HBUS 4-In 2-Out Wiegand (C300665): IDEMIA (Morpho) Wiring, HBUS 4 in 2 Out Door Module, Wiegand Variant.
Older Sigma hardware can need a related wiring fix when a reader is failing to come back online after updating its mode or database: two isolating diodes on D0 and D1. See IDEMIA reader does not come online after an update.