Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Install IDEMIA reader software and firmware

Install IDEMIA (Morpho) drivers, licenses, MBTB tools, and compatible reader firmware.

Detailed steps are in "MorphoAccess Installation.pdf" (in ~\Morpho Utilities on the Gallagher install media). The quick install order is:

  1. SafeNet or Morpho ACS Biometric Dongle Driver (~\Morpho Utilities\Device Drivers).

  2. Smart Driver (MorphoSmart) (~\Morpho Utilities\Device Drivers\MorphoSmart).

  3. License Manager (Morpho License Manager 4.10.0; version varies with the release), from ~\Morpho Utilities\License Manager.

  4. Verif Dongle License. The dongle serial number on your dongle must match the dongle licence provided. The physical Verif Dongle must be plugged into each Command Centre server pre-7.80, and into any biometric-capturing workstations (Gallagher order Part C864401).

  5. Microsoft Redistributables (~\Morpho Utilities\Microsoft Redistributes). Install all the executable files in this folder.

  6. Correct firmware on the Morpho MSO enrolment device(s).

Firmware (4.5.1+)

  • From version 4.5.1 onward, legacy mode needs the 2G 4.5.1 firmware and standard mode needs the 5G 4.5.1 firmware. Otherwise MBTB will not connect and the reader does not work.

  • Firmware versions 4.5.1 and 4.5.2 come in 2 versions: MA2G (Legacy, non-encrypted) and MA5G (encrypted).

  • New Sigma readers ship 4.5.2 MA5G+ (4.5.2 MA5G firmware or later). To connect to pre-7.80 systems, install the MA2G firmware. A time will come when MA2G Sigma firmware is no longer available.

  • Gallagher does not control IDEMIA's shipped firmware, that is, the firmware version IDEMIA releases the hardware with.

Which firmware to install for each comms mode: MA2G and MA5G communication modes.

Wiring

The related wiring steps for Sigma readers over Wiegand (power, data, and the wiring diagram) are on Wire IDEMIA readers over Wiegand.

Before you begin

If Morpho is already installed and you are upgrading your system, remove the Morpho-related drivers and software from the Command Centre server and any workstation that will capture biometrics:

  1. Remove the dongle and any biometric enrolment devices.

  2. In the Windows Add or Remove Programs utility, remove: Morpho MorphoSmart USB Drivers, Sentinel Protection Installer 7.x.x, Morpho Integrators Kit, and Morpho License Protection.

  3. Upgrade the Morpho-related drivers and software to the versions in the steps below.

All Morpho resources and documents are in the Utilities\Morpho folder of the Command Centre installation files, available from the ftp server or on DVD on request. More detail is in the Morpho License Manager User's Guide (Morpho License Manager UG.pdf, in Utilities\Morpho\Documentation).

Microsoft redistributables

Install the Microsoft Visual Studio Redistributables (32-bit and 64-bit) on the capture workstation and the server.

  1. Go to the Utilities\Morpho\Microsoft Redistributables folder of the Command Centre installation files. VC10redist_x86, VC12redist_x86, VC14redist_x86 and VC14redist_x64 are required.

  2. Open the vc10redist_x86 folder and run the executable. Work through each screen.

  3. Open the vc12redist_x86 folder and run the executable. Work through each screen.

  4. Open the vc14redist folder and run VC_redist.x86 and VC_redist.x64. Work through each screen.

  5. Restart the computer.

USB/MSO dongle driver

The biometric dongle driver must be installed on the Command Centre server and any workstation that will capture biometrics. Either of these works with Command Centre:

  • SafeNet dongle: USB VERIF (Part No. C864401) or USB IDENT (Part No. C864403/C864405)

  • Morpho ACS dongle: V2 USB VERIF (Part No. C864510) or USB IDENT (Part No. C864515)

  • Morpho MSO dongle: MSO VERIF (Part No. C864501)

For the dongle and licence variants, see Verif licenses and dongle variants.

SafeNet - VERIF / IDENT dongle type:

SafeNet VERIF dongle (label covered)
  1. Locate and run Sentinel System Driver Installer 7.6.0.exe (as Administrator) in Utilities\Morpho\Device Drivers\SafeNet Dongle. The Welcome screen of the InstallShield Wizard displays.

    Sentinel System Driver Installer 7.6.0 InstallShield Wizard, Welcome screen
  2. Click Next. The License Agreement screen displays.

  3. Click I accept the terms in the license agreement, then Next. The Setup Type screen displays.

  4. Click Complete, then Next. The Ready to Install the Program screen displays.

  5. Click Install. When installation completes, the Completed screen displays.

  6. Click Finish.

  7. Plug the Morpho dongle into a USB port.

Morpho ACS - VERIF / IDENT dongle type:

Morpho ACS ACR38T dongle with its SIM (serial covered)
  1. Locate and run Setup.exe (as Administrator) in Utilities\Morpho\Device Drivers\Morpho Dongle (ACS). A Setup screen displays.

    ACS driver Setup: Choose your language
  2. Select your language and click OK. The Welcome screen of the installation wizard displays.

    ACS Unified PC/SC Driver 4.0.0.7 Setup Wizard, Welcome screen
  3. Click Next. The Destination Folder screen displays.

  4. Select the installation directory and click Next. The Ready to install screen displays.

  5. Click Install. When installation completes, the Completed screen displays.

  6. Click Finish.

  7. Plug the Morpho dongle into a USB port.

MSO330 and MSO FVP drivers

  1. Go to Utilities\Morpho\Device Drivers\MorphoSmart.

  2. Open the folder for your operating system: x64 for 64-bit, or x86 for 32-bit.

  3. Run Setup.exe as Administrator. The Welcome screen of the InstallShield Wizard displays.

    MorphoSmart USB 64 bits Driver 3.59.1.0 InstallShield Wizard, Welcome screen
  4. Click Next. The Destination Folder screen displays.

  5. To change the installation directory click Change…; otherwise click Next. The Ready to Install the Program screen displays.

  6. Click Install. You may be asked to validate installation of the driver. When installation completes, the Completed screen displays.

  7. Click Finish. The wizard closes and a "Restart PC" pop-up displays.

  8. Click No. The PC does not need restarting until after you install the License Manager.

MorphoAccess readers: IP address

  • Configuring a biometric reader: readers must be configured with their IP address to be available on the network. Default IP address: 192.168.1.10.

  • Configuring your machine: first set your machine's network so it can talk to the reader's default address, for instance by giving the PC 192.168.1.100. Check IP communication between the PC and the reader before going on: open a command prompt and ping the reader.

To set the address from a web browser instead, see Set a MorphoWave reader's IP address in a web browser.

MorphoBioToolBox (MBTB)

Before you install MBTB, install:

  • the Microsoft Visual C++ 2022 Redistributable Package (Utilities\Morpho\Microsoft Redistributables\vc14redist): run VC_redist.x64;

  • ndp48-web .NET Framework 4.8 (Utilities\Morpho\dotNet Framework).

Install:

  1. Copy MorphoBioToolBox (MBTB) X.X.XX.exe from Utilities\Morpho\MorphoBioToolBox to any directory on your local drive, and run it. The Welcome screen of the MorphoBio ToolBox Setup Wizard displays.

    MorphoBioToolBox Setup, Welcome screen
  2. Click Next. The License Agreement screen displays.

  3. Click I Agree. The Choose Install Location screen displays.

  4. Choose the destination folder and click Install. The Completion screen displays when the product is installed.

  5. Click Finish.

Configure:

  1. Double-click the MBTB icon on your desktop.

    MBTB desktop icon
  2. If the reader is locked, unlock it first. Any Morpho reader with a serial number greater than 2242xxxxxxxxxx has On-demand Security state enabled out of the box, and you must use MBTB v4.6.12 or later for this to work. Follow Enable On-Demand Security, then connect to the reader on port 11010 with TLS Configuration None.

  3. Change the reader's IP address: click the Communication Configuration tab and change the IP address settings.

    MBTB Communication Configuration, IP Address Settings: Ethernet, IPv4, static, IP address 192.168.1.10, network mask 255.255.254.0, gateway 192.168.1.254, host name MorphoWaveSP, preferred DNS 1.1.1.1, alternate DNS 2.2.2.2, Write and Read

    Set the Preferred DNS and Alternate DNS as shown by default (you cannot leave the 0.0.0.0 value).

  4. Click Write to apply the new IP settings. This disconnects the device. To reconnect, change your machine's IP settings, or connect the device to its final network and connect from a machine on that network.

  5. Click Device Settings, then the Date and Time tab. Set the correct time and time zone for the site and click Write. The message "Date and time settings written successfully to device" appears. Click OK.

    MBTB Device Settings, Date and Time tab: date, time, predefined time zone, Read and Write
    MBTB Date and Time tab with the time zone and Write

Last updated