Disable biometric authentication for a card
Configure MBTB settings for card-only access on IDEMIA (Morpho) biometric readers.
You can disable biometric on a card encoded with the Morpho MIFARE object set to Card Number + Biometric, without re-encoding it to Card Number only. Change the configuration keys below in MBTB (Biobox Toolbox) for card-only user authentication. Click the green tick to apply each change.
The keys depend on the reader and its protocol: Legacy protocol (MA100/120, MA J, MA520, OMA520), Native MA5G (Sigma Lite, Sigma, Extreme), or Sigma in Legacy MA2G.
Legacy protocol readers
This applies to MA100/120, MA J Series, MA520 and OMA520 readers only. It does not apply to MA Sigma range readers in Legacy mode (MA2G).
app/bio ctrl/bypass authentication=1(default =0)
Native mode (MA5G) Sigma readers
This applies to MA Sigma readers: MA Sigma Lite, MA Sigma and MA Sigma Extreme.
ucc.Finger_bio_auth_rule=0(default =0)ucc.per_user_rules=0(default =1)ucc.trigger_event=3(default =3)
Sigma readers in Legacy mode (MA2G)
This applies to MA Sigma Lite, MA Sigma and MA Sigma Extreme readers in Legacy mode. Change these configuration keys:
app/bio ctrl/authent card mode=0app/bio ctrl/authent ID contactless=0app/bio ctrl/authent PK contactless=1app/bio ctrl/bypass authentication=1
To confirm reader behaviour after the change, see Collect IDEMIA diagnostic logs.