Collect ThyssenKrupp Elevator Service diagnostics
Collect ThyssenKrupp Elevator Service configuration, server, activity, and controller logs for investigation.
Collect these details before escalating a ThyssenKrupp HLI issue. Reproduce the issue before collecting logs where possible.
Capture configuration details
Capture all tabs of the ThyssenKrupp Elevator System item properties.
Record the Log Level on the Configuration tab.
Record the Command Centre version and controller firmware version.
Enable diagnostic logging
Set the
GeneralOnregistry value to1.Set the
LogFileCountregistry value to10.Set the Elevator System item's Log Level to Trace or Debug.
The registry path is Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Gallagher\Command Centre.
Remove the debug settings after investigation. Set GeneralOn to 0 and restore the default log level.
Collect server and activity logs
Enable Trace On in CCFT Service Manager.
Run SupportLogTool on the Gallagher server with elevated privileges.
Generate a Configuration Client Activity Report as a text file.
Use the period when the issue occurred or was reproduced.
Collect controller logs
Use SupportLogTool or FTSupportTool to collect FTSupportInfo.txt. Capture the logs within one hour because busy controllers can overwrite them within 15 minutes.
For a test period, use repeated controller-log collection. Stop collection after testing, then compress the generated files before sending them to Technical Support.