Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Elevator integration interfaces and limits

Compare elevator interface types, controller limits, port use, and performance guidance.

Gallagher integrates with four major elevator brands via three distinct interface methods. The interface type drives the wiring, software configuration, and item type used in Command Centre.

Supported brands: Kone, Otis, Schindler, ThyssenKrupp.

Two elevator system types

Type
How it works

Conventional dispatching

Any available lift serves any request. Passengers select their own floor inside the car.

Destination-based dispatching

The system groups passengers by destination floor before they enter and assigns a specific car.

Conventional dispatching concept - scatter diagram showing undirected assignment
Conventional dispatching - one lift serves all requests while others sit idle

Conventional: all passengers compete for the same available lift. Other cars sit idle.

Destination-based dispatching concept - scatter diagram showing grouped assignment by colour
Destination-based dispatching - Lift A assigned floors 10-15, Lift C assigned floors 25-35

Destination-based: the system pre-assigns lifts by floor group before passengers board.

Three interface types

RS232 - Wired Serial Cable

Used by: Kone (standard), Otis, Otis Modbus, Schindler, ThyssenKrupp v7.10+.

A physical serial cable connects the C6000's RS232 port directly to the elevator system panel.

RS232 architecture - Gallagher server and workstation connected to C6000 via RS232 serial cable, C6000 wired to 3 lifts and Elevator System Group Control

Requirements:

  • RS232 cable wired to the controller hardware port.

  • Elevator HLI item configured in Command Centre under Controller > Serial Devices tab.

C6000 Properties - Serial Devices tab showing Elevator HLI field set to Kone ELI HLI

TCP/IP - Network Connection

Used by: Kone ELI, Otis Compass, Schindler system variants.

No physical serial cable. Communication goes over LAN. The controller's Serial Device software slot is still used, but the RS232 hardware port is not.

TCP/IP architecture - Gallagher server on LAN, C6000 communicating with Elevator System Group Control over network with 3 lifts

Note: Even without a cable, the controller's Serial Device slot is consumed and unavailable for other purposes. The Elevator HLI item is still required for some variants.

Schindler note: Requires a middleware machine, which is unique among all integrations.

Schindler-specific - External Systems tree in Command Centre showing SchindlerID System, Live Reporting, and Call Manager items

Gallagher Elevator Service - TCP/IP with Service Layer

Used by: Kone Office Flow, ThyssenKrupp v8.10-8.30, ThyssenKrupp Insight (v8.40+).

A separate Windows service (GGL Elevator Service) sits between the Gallagher server and the elevator system. This is the most modern integration path.

GGL Elevator Service architecture - Gallagher server bidirectional with GGL Elevator Service, both on LAN, C6000 connects to 3 lifts and Elevator System Group Control

Key difference: Uses the Elevator System item type in Command Centre, not Elevator HLI. There is no dependency on the controller's Serial Device slot or RS232 port.

HLI comparison table

HLI comparison table - all supported vendors showing interface type, RS232 port usage, Gallagher Elevator Service requirement, and CC item type

RS232 Port column values:

Value
Meaning

use

Physical serial cable required and connected to the controller port

consume

No cable needed but the port is locked and cannot be used for other purposes

unused

Port remains free for other purposes

For the full compatibility matrix including CC version requirements, refer to the CC Compatibility Matrix.

System limits (C6000)

Parameter
Limit
Notes

Levels per elevator car

256

-

Elevator cars per controller

8

Max configuration size per C6000

Transactions per second

2

Across all access items (doors and lifts) on that controller

In practice the binding limits are 20 HBUS readers per controller and 2 events per second per controller.

Performance guidelines

  • Place the Elevator Car HLI item and its reader on the same controller.

  • Use one access group covering all required levels rather than multiple single-level groups. This reduces transaction overhead significantly.

  • Use the "Change to Disarmed state" Alarm Zone privilege sparingly, as it significantly impacts response time. If used, keep the Alarm Zone on the same controller as the elevator car.