For the complete documentation index, see llms.txt. This page is also available as Markdown.

Error while connecting to specified server: Interface not regis

Command Centre - Connection Issues › Interface not registered

Error: "Interface not registered" from the OPC Bridge Configuration tool.

Cause: three proxy/stub DLLs in the Command Centre Bin folder need to be registered manually.

Resolution

  1. Open a Command Prompt and run as administrator.

  2. Locate the Bin folder (default C:\Program Files (x86)\Gallagher\Command Centre\Bin):

    cd C:\Program Files (x86)\Gallagher\Command Centre\Bin
  3. Register the three DLLs:

    regsvr32 opc_aeps.dll opccomn_ps.dll opcSec_PS.dll
  4. You will receive three messages confirming each DLL registered successfully.

Then try to connect to the OPC Server in the OPC Bridge Configuration tool again.

Interface not registered error