Error while connecting to specified server: Interface not regis
Command Centre - Connection Issues › Interface not registered
Error: "Interface not registered" from the OPC Bridge Configuration tool.
Cause: three proxy/stub DLLs in the Command Centre Bin folder need to be registered manually.
Resolution
Open a Command Prompt and run as administrator.
Locate the Bin folder (default
C:\Program Files (x86)\Gallagher\Command Centre\Bin):cd C:\Program Files (x86)\Gallagher\Command Centre\BinRegister the three DLLs:
regsvr32 opc_aeps.dll opccomn_ps.dll opcSec_PS.dllYou will receive three messages confirming each DLL registered successfully.
Then try to connect to the OPC Server in the OPC Bridge Configuration tool again.


🔗 Related
error while connecting to specified server: Method '
' of object '' failed. The next OPC Bridge error.
PreviousWorkstations located across a large geographic area
NextError while connecting to specified server: Method '' of object
Last updated