Command Centre Client limits (head end)
Alarm Comments: 1024 characters
Status Viewer: 24 panes, with a maximum of 100 items per pane
Related to search: maximum of 10 items in the "related to" field
Cardholder Wizard: maximum of 1000 cardholders at a time
What limits do actions plans have?
An action plan can have up to 256 output items within it.
What other limits does Command Centre have?
Default Club (Access Group) capacity of a controller = 2000
Default Diary (Schedule) capacity = 400
What are the access zone limits?
A maximum of 256 access zones per controller.
A maximum of 16 card facility codes per controller.
As of 7.90: up to 256 third-party facility codes can be supported (non-Gallagher encoded cards). The limit of 16 facility codes remains for Gallagher encoded cards.
T-Series readers are configured with the first 16 facility codes to assist them in identifying Gallagher data sectors to read.
What are the alarm zone limits?
A maximum of 255 alarm zones per controller.
An alarm zone requires a part input against the controller's alarm part. Because of the limit of inputs per part, there can only be 255 zones per controller.
What are the interlock group limits?
Maximum of 20 doors per interlock group.
Remote Arming Terminal (RAT) / Keypad
Maximum alarm zones managed by a keypad = 30
Maximum inputs to monitor = 100
Maximum fence zones to monitor = 50
What is the logic block limit?
Maximum logic rules = 10