Cardholder count outputs
Control outputs from access-zone occupancy counts.
Cardholder Count Outputs turn Outputs On and Off by Access-Zone occupancy. An Output assigned to an Access Zone turns On when the cardholder count goes from 0 to 1, and Off when it goes from 1 to 0. This is used to tell third-party systems which zones are empty or occupied.
Parent and child behaviour: a parent zone's count includes all child zones. For example, take 'Building 1' (parent) with 'Room 1' (child). Entering Building 1 turns its Output On. Entering Room 1 turns Room 1's Output On, and Building 1 stays On. Building 1's Output stays On until the last cardholder leaves the site.
Supported on v8.40 to v9.20.