For the complete documentation index, see llms.txt. Markdown versions of documentation pages are available by appending .md to page URLs.
Skip to content

Deactivate a siren after a delay or alarm-zone disarm

Configure virtual outputs and logic blocks to deactivate a siren automatically.

This configuration turns a siren off automatically after a set delay (10 minutes in the example) or when the alarm zone is disarmed. It uses two virtual outputs and three logic blocks.

Create two Virtual Outputs:

  • VO Alarm Armed

  • Event Response

Create three Logic Blocks:

  • Latched On

  • Delay

  • Clear Logic

Wire the configuration

  1. Add VO Alarm Armed to the Reflected output tab of the alarm zone.

VO Alarm Armed on the alarm zone reflected output tab
  1. Make sure the access zone has the correct alarm zone assigned on its Event Response tab.

Access zone Event Response tab
  1. Add the Event Response virtual output to the Armed tab of a new action plan.

Event Response VO on the action plan Armed tab
  1. Assign the new action plan to the PIR's Event Response. In the example, the action plan is assigned to Closed/On as the PIR is Normally Open. Also assign the PIR to the correct alarm zone.

PIR Event Response with the action plan assigned

Logic Block 1: Latched On

Logic Block 1 Latched On configuration
Logic Block 1 Latched On configuration continued
Logic Block 1 Latched On configuration continued

Logic Block 2: 10-minute delay (countdown)

Logic Block 2 delay countdown
Logic Block 2 delay countdown continued

Logic Block 3: Reset latch logic block

Logic Block 3 reset latch
Logic Block 3 reset latch continued

Result: the siren activates on alarm, then deactivates automatically once the delay (10 minutes in the example) elapses, or when the alarm zone is disarmed.

Last updated

Was this helpful?