Access zones
Configure physical access zones for anti-passback, mustering, and occupancy tracking.
An access zone is a physical area within a site that cardholders move between via controlled doors. When a cardholder badges through a door, they transition from one zone to another. Zones enable three high-value capabilities:
Anti-passback (APB): prevents tailgating by enforcing "you must exit before re-entering."
Mustering / roll call: knowing who is in which zone during an emergency evacuation.
Zone counts: how many cardholders are currently in each zone (occupancy management).
How zones work
Doors define transitions between access zones. A door has an entry side and an exit side, each connected to an access zone:
[Outside Zone] --Reader Out--> [Lobby Zone] --Reader Out--> [Office Floor Zone]
<--Reader In-- <--Reader In--When Pete badges at the lobby door from outside:
His current zone changes from "Outside" to "Lobby".
The system records the transition and timestamp.
The Lobby zone count increments.
When Pete badges into the Office Floor:
Lobby count decrements, Office Floor count increments.
Pete's zone is now "Office Floor".
Anti-passback (APB)
The problem APB solves: tailgating. A cardholder badges in, then holds the door for a buddy who did not badge.
How APB enforces: if APB is enabled, the system rejects a re-entry attempt to a zone the cardholder is already in. They have to badge out first.
Modes:
Hard APB: re-entry rejected outright.
Soft APB: re-entry permitted but logged as a violation (useful for non-critical sites).
Timed APB: re-entry rejected only if attempted within N minutes.
Limitations:
APB requires both readers at the door (entry and exit).
A door with only an entry reader cannot do APB cleanly.
APB enforcement breaks if a cardholder leaves via an unmanned door (for example an emergency exit).
Mustering / roll call
In an emergency (evacuation, drill, lockdown), the operator needs to know who is where. Access zones enable this:
Each cardholder's current zone is tracked.
The operator pulls a "who is in zone X" report.
This is compared against expected presence to identify people unaccounted for.
For perimeter sites, zone tracking includes outdoor zones (carparks, perimeter approach areas), which is useful for site-wide mustering.
Caveats:
Mustering is only as good as the badging discipline. People who tailgate or leave without badging are "still in" their last known zone.
Manual zone overrides (an operator changes a cardholder's zone) help correct discipline gaps.
Zone counts
The current occupancy of each zone, displayed on:
Command Centre Client (zone count tile)
Site Plans (visual occupancy on a floor plan)
Reports (historical occupancy patterns)
Use cases:
Capacity management (do not exceed N people in a zone)
Distancing thresholds
Visitor escort verification (X visitors in an escort area)
Perimeter monitoring (how many vehicles in a carpark)
Zones and alarm states
A cardholder's access can depend on the alarm state of the zone they are entering:
An access zone can be assigned an alarm zone.
When the alarm zone is armed, cardholders without "disarm" privilege are denied.
When disarmed, normal access rules apply.
This is the bridge between access control and intruder alarms. A cardholder in an access group with the "Change to Disarmed state" privilege can disarm the zone by badging, granting them access and turning off the alarm in one action.
Configuration ordering
Access zones depend on schedules being configured first. The order is:
Divisions
Day Categories
Schedules (access zone schedules live here)
Controllers
Alarm Zones
Access Zones
Doors (assign each door's entry and exit access zones)
Readers
Inputs
Outputs
Access Groups (reference access zones)
Cardholders
Common mistakes
Forgetting to assign access zones to a door. The door works for access but the system cannot track zone transitions, breaking APB and mustering.
APB enforcement on a door without two readers. APB requires entry and exit readers. Single-reader doors cannot enforce cleanly.
Mismatched zone topology. If two doors define inconsistent zone transitions (Door A says "Lobby to Office", Door B says "Outside to Office") cardholders get into illogical states.
Site plans not updated. Zone counts only display correctly if site plan zone shapes are drawn. This is easy to skip during commissioning.
"Why does a reader with no keypad ask for a PIN?" The security level is shared across all the readers on a door, by design: see below.
Security level is shared across all readers on a door
This is by design. Take a door with readers on both sides and a different access zone on each side:

Access zones. If the Entry Access Zone is set to Secure + PIN, the Exit Access Zone on the other side of the door adopts the same security level:
Reader 1 and Reader 2 require a card and PIN to gain access (yes, even Reader 1, which has no way to enter a PIN).
On the other side of the door, Reader 3 and Reader 4 also require a card and PIN.
If an access zone on one side of the door is set to a higher access setting, the other side always matches that level.
Readers. If Reader 1 is set to require a second factor, the other reader on that side of the door (Reader 2) also requires a second factor.

The reason: with an upper and a lower reader (the lower one for accessible access, for example), if the lower one did not need the second factor, everyone would use it because it is easier.
🔗 Related
Command Centre - Access Groups. The policy layer that grants access to zones and doors.
Command Centre - Alarm Zones. Event management zones, distinct from access zones.
Last updated
Was this helpful?