Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Use alarm zones for perimeter security

Configure perimeter members, responses, and safe arming.

Use alarm zones for perimeter security

Perimeter sensors are alarm-zone members. These include Z20 vibration sensors, fence energizer zones, and gate tampers.

A typical site uses:

  • One default alarm zone per controller for general access-control items.

  • Dedicated perimeter alarm zones for fence and gate devices.

  • Perimeter action plans for breach response and escalation.

Use a perimeter-specific action plan. It can instruct operators to call patrol, escalate to the SOC, and capture CCTV. Generic door-alarm responses do not provide enough context.

Avoid common mistakes

  1. Attach every door, reader, and tamper input to an alarm zone.

  2. Keep every alarm zone on one controller.

  3. Use Fail to arm for perimeter zones unless an exception is justified.

  4. Provide manual override for schedule-controlled zones.

For monitoring integration, the alarm-zone Group Identifier maps to alarm transmission. See Alarm Transmission - Monitoring.