Configure alarm zones

Create, connect, and initialize alarm zones.

Configure alarm zones

An alarm zone groups doors, readers, inputs, and fence zones. It manages events and alarm state. Every door, reader, and tamper input needs an alarm zone. Otherwise, events do not log and alarms do not fire.

Use one default alarm zone per controller. Do not span alarm zones across controllers. An offline controller can compromise a multi-controller alarm zone.

Alarm zones are not access zones. Access zones define physical movement. Alarm zones manage events and alarm responses.

What an alarm zone defines

Element
Purpose

Division

Identifies the owning tenancy.

Controller

Identifies the C7000 or C6000 hosting the zone.

Members

Includes attached doors, readers, inputs, outputs, and fence zones.

Event Defaults

Defines operator action plans for zone alarms.

State control

Defines manual, scheduled, or key-switch arming.

Arming behaviour

Defines force arm, input isolation, or failure to arm.

Create and initialize a zone

  1. Go to Configure → Alarm Zones → New.

  2. Enter the name and division on General.

  3. Select the controller under Connections.

  4. Configure event defaults, state changes, and advanced arming behaviour.

  5. Apply the configuration.

  6. Associate inputs with the alarm zone.

Inputs report state changes. The alarm zone evaluates those changes.

Installation order

Configure alarm zones after divisions, day categories, schedules, and controllers. Configure them before access zones, doors, readers, inputs, outputs, access groups, and cardholders.