Configure alarm zones
Create, connect, and initialize alarm zones.
Configure alarm zones
An alarm zone groups doors, readers, inputs, and fence zones. It manages events and alarm state. Every door, reader, and tamper input needs an alarm zone. Otherwise, events do not log and alarms do not fire.
Use one default alarm zone per controller. Do not span alarm zones across controllers. An offline controller can compromise a multi-controller alarm zone.
What an alarm zone defines
Division
Identifies the owning tenancy.
Controller
Identifies the C7000 or C6000 hosting the zone.
Members
Includes attached doors, readers, inputs, outputs, and fence zones.
Event Defaults
Defines operator action plans for zone alarms.
State control
Defines manual, scheduled, or key-switch arming.
Arming behaviour
Defines force arm, input isolation, or failure to arm.
Create and initialize a zone
Go to Configure → Alarm Zones → New.
Enter the name and division on General.
Select the controller under Connections.
Configure event defaults, state changes, and advanced arming behaviour.
Apply the configuration.
Associate inputs with the alarm zone.
Inputs report state changes. The alarm zone evaluates those changes.
Installation order
Configure alarm zones after divisions, day categories, schedules, and controllers. Configure them before access zones, doors, readers, inputs, outputs, access groups, and cardholders.