Ademco format
Reference Ademco Contact ID fields, DC-09 packet structure, and event codes.
Command Centre transmits alarm events in the Ademco Contact ID format over both Analog (PSTN dialler) and IP (DC-09) transports. This page is the format reference. For how to set up monitoring and diallers, see Alarm Transmission - Monitoring.
Alarm Dialler format (PSTN)
The Alarm Dialler (Dialer in the USA) is a component that uses an RS232 (serial) port to connect to a PSTN dialler and send messages using ADEMCO Contact ID, an industry standard across the world since 1999.
The format of the message is:
ACCT MT Q XYZ GG CCCACCT
4-digit account number (0-9, B-F). Set in either the System Properties or in the Alarm Zone itself.
MT
Message Type. A 2-digit sequence identifying the Contact ID message to the receiver. Transmitted as either 18 (preferred) or 98 (optional). New receiver implementations accept either; some older receivers may not accept 98.
Q
Event qualifier: 1 = New Event or Opening; 3 = New Restore or Closing; 6 = Previously reported condition still present (status report).
XYZ
Event code (3 hex digits, 0-9, B-F). Decided by the event type selected at the Input Properties. See the addendum table below.
GG
Group or Partition number (2 hex digits, 0-9, B-F). This is the Alarm Zone in Command Centre. Use 00 to indicate no specific group or partition applies.
CCC
Zone number (event reports) or User # (open/close reports), 3 hex digits (0-9, B-F). Use 000 to indicate no specific zone or user applies.
IP Alarm Transmitter format (DC-09 packet)
The IP Alarm Transmitter sends messages directly from the controller to a monitoring station over TCP/IP instead of a phone line. It has two protocol options, CSV and DC-09. The following explains how the DC-09 message is composed and how it relates to ADEMCO Contact ID.
A controller's outgoing message, observable in the controller's debug webpage under Parts Manager > Alarm Transmitter Part, may look like:
"ADM-CID"0005L98765#001235[#001235|1423 44 777]_17:15:19,03-06-2026
"ADM-CID"0006L98765#001235[#001235|3423 44 777]_17:15:30,03-06-2026The format is:
The second half (between | and ], which DC-09 calls the DATA) is almost identical to the Alarm Dialler format, except there is no MT. The ACCT is sent as 6 digits, so an ACCT of 1235 in Command Centre is padded to 001235.
Aside from time and date, there are four new components: ID, SEQ, LLLLL, RI:
ID
The format, always "ADM-CID" within Command Centre. Tells the receiver we are using ADEMCO Contact ID format in the DATA.
SEQ
The sequence of messages (for example 0005, then 0006 on the next message).
LLLLL
Line Card. In Command Centre this is called the Prefix. For American monitoring stations this is typically known as DNIS, despite that being an antiquated term.
RI
Receiver ID. The field that causes the most confusion.
Receiver ID behaviour changed by version
RI is intended to be an ID for the device sending the message (a panel ID, or a Transmitter ID as Command Centre calls it). However, Command Centre versions v8.70.2078+ (MR3+), v8.80.1025+ (MR1+) and v8.90+ behave differently since the Prefix field was added:
If Prefix is set to 0 then the old behaviour remains: the Transmitter ID is sent in this field.
If Prefix is populated with something other than 0 then the 6-digit ACCT is sent (as in the two examples above).
How it looks in the Configuration Client:

Note: The Gallagher IP Alarm Receiver software is still able to receive messages, as long as the 6-digit value of ACCT is configured in the field the receiver software calls Transmitter ID.
Addendum: XYZ event code list
The following is the internationally accepted Contact ID event code list. Note that this is the standard list, not necessarily the event Command Centre will transmit.
100
Medical
Zone
A non-specific medical condition exists
101
Personal Emergency
Zone
Emergency Assistance request
102
Fail to report in
Zone
A user has failed to activate a monitoring device
110
Fire
Zone
A non-specific fire alarm condition exists
111
Smoke
Zone
An alarm has been triggered by a smoke detector
112
Combustion
Zone
An alarm has been triggered by a combustion detector
113
Water Flow
Zone
An alarm has been triggered by a water flow detector
114
Heat
Zone
An alarm has been triggered by a heat detector
115
Pull Station
Zone
A pull station has been activated
116
Duct
Zone
An alarm has been triggered by a duct detector
117
Flame
Zone
An alarm has been triggered by a flame detector
118
Near Alarm
Zone
A near-alarm condition has been detected on a fire sensor
120
Panic
Zone
A non-specific hold-up alarm exists
121
Duress
User
A duress code has been entered by a user
122
Silent
Zone
silent hold-up alarm exists
123
Audible
Zone
An audible hold-up alarm exists
124
Duress - Access granted
Zone
A duress code has been entered and granted at an entry door
125
Duress - Egress granted
Zone
A duress code has been entered and granted at an exit door
126
Hold-up suspicion print
User
A user has activated a trigger to indicate a suspicious condition
129
Panic Verifier
Zone
A confirmed Hold-up condition exists
130
Burglary
Zone
A burglary zone has been violated while armed
131
Perimeter
Zone
A perimeter zone has been violated while armed
132
Interior
Zone
An interior zone has been violated while armed
133
24 Hour (Safe)
Zone
A 24 hour burglary zone has been violated
134
Entry/Exit
Zone
An Entry/Exit zone has been violated while armed
135
Day/Night
Zone
An trouble by Day / alarm by Night zone has been violated while armed
136
Outdoor
Zone
An outdoor burglary zone has been violated while armed
137
Tamper
Zone
A burglary zone has been tampered with while armed
138
Near alarm
Zone
A burg sensor has detected a condition which will cause it to go into alarm if the condition worsens
139
Intrusion Verifier
Zone
The specified zone has verified that an intrusion has occurred
140
General Alarm
Zone
The specified zone is in an alarm condition
141
Polling loop open
Zone
An open circuit condition has been detected on a polling loop while the system was armed
142
Polling loop short
Zone
A short circuit condition has been detected on a polling loop while the system was armed
143
Expansion module failure
Zone
A general failure condition has been detected on an expansion module while the system was armed
144
Sensor tamper
Zone
A sensor's tamper has been violated (case opened)
145
Expansion module tamper
Zone
An expansion module's tamper has been violated (cabinet opened)
146
Silent Burglary
Zone
A burglary zone has been violated while armed with no audible notification produced
147
Sensor Supervision Failure
Zone
A sensor's supervisory circuit has reported a failure while the system was armed
150
24 Hour Non-Burglary
Zone
A non-burglary zone has been faulted
151
Gas detected
Zone
The gas detector assigned to the specified zone has reported a fault condition
152
Refrigeration
Zone
The refrigeration detector assigned to the specified zone has reported a fault condition
153
Loss of heat
Zone
The temperature detector assigned to the specified zone has reported a fault condition
154
Water Leakage
Zone
The water leak detector assigned to the specified zone has reported a fault condition
155
Foil Break
Zone
The specified zone which is assigned to foil used as glass break detection has reported a fault condition
156
Day Trouble
Zone
The specified zone which monitors trouble by day has reported a fault condition while disarmed
157
Low bottled gas level
Zone
The gas level detector assigned to the specified zone has reported a fault condition
158
High temp
Zone
The over-temperature detector assigned to the specified zone has reported a fault condition
159
Low temp
Zone
The under-temperature detector assigned to the specified zone has reported a fault condition
161
Loss of air flow
Zone
The air flow detector assigned to the specified zone has reported a fault condition
162
Carbon Monoxide detected
Zone
The carbon monoxide detector assigned to the specified zone has reported a fault condition
163
Tank level
Zone
The tank level detector assigned to the specified zone has reported a fault condition
168
High Humidity
Zone
A High Humidity condition has been detected
169
Low Humidity
Zone
A Low Humidity condition has been detected
200
Fire Supervisory
Zone
The supervisory circuit of the specified fire zone has reported a fault condition
201
Low water pressure
Zone
The water pressure sensor assigned to the specified zone has reported a fault condition
202
Low CO2
Zone
The CO2 pressure sensor assigned to the specified zone has reported a fault condition
203
Gate valve sensor
Zone
The gate valve sensor in the fire sprinkler system assigned to the specified zone has reported a fault condition
204
Low water level
Zone
The water level sensor assigned to the specified zone has reported a fault condition
205
Pump activated
Zone
The pump activity detector assigned to the specified zone has reported an active condition
206
Pump failure
Zone
A pump output monitor assigned to the specified zone has reported a fault condition
300
System Trouble
Zone
A general system trouble condition has been reported by the specified zone
301
AC Loss
Zone
AC power loss has been detected at a control or expansion module while the system was disarmed
302
Low system battery
Zone
A battery has failed a load test while the system was disarmed
303
RAM Checksum bad
Zone
A test of the system's memory has failed
304
ROM checksum bad
Zone
A test of the system's executable memory has failed
305
System reset
Zone
The system has reset and restarted
306
Panel programming changed
Zone
The programmed configuration of the panel has changed
307
Self-test failure
Zone
The system has failed a self-test
308
System shutdown
Zone
The system has been shut down and has stopped functioning
309
Battery test failure
Zone
The system backup battery has failed a load test while the system was disarmed
310
Ground fault
Zone
The panel has detected a ground fault condition
311
Battery Missing/Dead
Zone
The system has detected that the backup battery is either missing or completely discharged.
312
Power Supply Overcurrent
Zone
The system power supply has reported an excessive current draw condition
313
Engineer Reset
User
The specified service person has issued a system reset
314
Primary Power Supply Failure
Zone
The system's primary power supply has failed a supervision test. Radio devices indicate this when the backup battery charging circuit has failed its supervision test
316
System Tamper
Zone
The system has been tampered with and may have been compromised
320
Sounder/Relay
Zone
A trouble condition exists in the system's sounder/relay circuit
321
Bell 1
Zone
A trouble condition exists in the primary bell circuit
322
Bell 2
Zone
A trouble condition exists in the secondary bell circuit
323
Alarm relay
Zone
A trouble condition exists in the system's alarm relay circuit
324
Trouble relay
Zone
A trouble condition exists in the system's trouble relay circuit
325
Reversing relay
Zone
The specified TELCO reversing relay has reported a trouble condition
326
Notification Appliance Ckt. # 3
Zone
A trouble condition exists in the bell #3 circuit
327
Notification Appliance Ckt. #4
Zone
A trouble condition exists in the bell #4 circuit
330
System Peripheral trouble
Zone
A system peripheral device has reported a trouble condition
331
Polling loop open
Zone
An open circuit condition has been detected on a polling loop while the system was disarmed
332
Polling loop short
Zone
A short circuit condition has been detected on a polling loop while the system was disarmed
333
Expansion module failure
Zone
A general failure condition has been detected on an expansion module while the system was disarmed
334
Repeater failure
Zone
A repeater in the system has reported a failure condition while the system was disarmed
335
Local printer out of paper
Zone
The printer attached to the panel has reported an Out Of Paper condition
336
Local printer failure
Zone
The printer attached to the panel has reported a failure condition
337
Exp. Module DC Loss
Zone
An expansion module has detected a DC power loss
338
Exp. Module Low Batt
Zone
An expansion module has detected a low battery condition
339
Exp. Module Reset
Zone
An expansion module has reset
341
Exp. Module Tamper
Zone
An expansion module has detected its taper switch has been faulted
342
Exp. Module AC Loss
Zone
An expansion module has detected the loss of AC power
343
Exp. Module self-test fail
Zone
An expansion module has failed a self-test
344
RF Receiver Jam Detect
Zone
An RF receiver has detected the presence of a jamming signal, preventing it from receiving normal signals from the system RF devices
345
AES Encryption disabled/ enabled
Zone
E345 AES Encryption has been disabledR345 AES Encryption has been enabled
350
Communication trouble
Zone
The system has experienced difficulties communicating with the central station
351
Telco 1 fault
Zone
The system has detected a fault on the primary dial-up line
352
Telco 2 fault
Zone
The system has detected a fault on the secondary dial-up line
353
Long Range Radio xmitter fault
Zone
A fault has been detected in the long range radio subsystem
354
Failure to communicate event
Zone
The system was unable to communicate an event to the central station
355
Loss of Radio supervision
Zone
The radio has not reported in its designated supervision interval
356
Loss of central polling
Zone
The radio has detected a loss in the polling signal from it's associated receiver
357
Long Range Radio VSWR problem
Zone
The Long Range Radio has reported a transmitter/antenna problem
358
Periodic Comm Test Fail /Restore
Zone
A periodic Communication path test has failed
370
Protection loop
Zone
The specified protection loop has reported a trouble condition
371
Protection loop open
Zone
The specified protection loop has reported an open-loop trouble condition
372
Protection loop short
Zone
The specified protection loop has reported a shorted-loop trouble condition
373
Fire trouble
Zone
A fire sensor has detected a trouble condition on the specified zone while the system was disarmed
374
Exit error alarm (zone)
Zone
An exit error condition has been reported for the specified alarm zone
375
Panic zone trouble
Zone
The system has detected a trouble condition on the panic zone
376
Hold-up zone trouble
Zone
The system has detected a trouble condition on the hold-up zone
377
Swinger Trouble
Zone
A fault has occurred on a zone that has been shut down due to excessive alarms
378
Cross-zone Trouble
Zone
The specified zone in a cross-zone configuration has faulted without a fault on its corresponding cross-zone in a specific time period
380
Sensor trouble
Zone
The specified sensor has reported a trouble condition
381
Loss of supervision - RF
Zone
The specified zone has failed to report in during its designated supervision period
382
Loss of supervision - RPM
Zone
An Remote Polled Module assigned to the specified zone has failed supervision
383
Sensor tamper
Zone
The tamper switch on the specified sensor has been faulted
384
RF low battery
Zone
The specified battery powered RF zone has reported a low battery condition
385
Smoke detector Hi sensitivity
Zone
A smoke detector's sensitivity level has drifted to the upper limit
386
Smoke detector Low sensitivity
Zone
A smoke detector's sensitivity level has drifted to the lower limit
387
Intrusion detector Hi sensitivity
Zone
An intrusion detector's sensitivity level has drifted to the upper limit
388
Intrusion detector Low sensitivity
Zone
An intrusion detector's sensitivity level has drifted to the lower limit
389
Sensor self-test failure
Zone
The specified sensor has failed a self-test
391
Sensor Watch trouble
Zone
A motion sensor has not been triggered within a pre-defined time interval
392
Drift Compensation Error
Zone
A smoke detector cannot automatically adjust its sensitivity
393
Maintenance Alert
Zone
The specified zone requires maintenance
394
CO Detector needs replacement
Zone
The specified Carbon Monoxide detector has reached end-of-life
400
Open/Close
User
The specified user has disarmed/armed the system
401
O/C by user
User
The specified user has disarmed/armed the system
402
Group O/C
User
A group of zones has been armed or disarmed
403
Automatic O/C
User
A partition has been automatically armed or disarmed
404
Late to O/C (Note: use 453 or 454 instead )
User
405
Deferred O/C (Obsolete- do not use )
User
406
Cancel
User
The specified user has cancelled the previously reported alarm condition
407
Remote arm/disarm
User
The specified user has armed or disarmed the system from off-premises
408
Quick arm
User
The specified user has quick-armed the system
409
Keyswitch O/C
User
The specified user has armed or disarmed the system using a keyswitch
411
Callback request made
User
A remote site (central station) has requested the panel call it back
412
Successful download/access
User
The configuration data of the system has been successfully downloaded
413
Unsuccessful access
User
A number of failed attempts have been made to remotely access the system
414
System shutdown command received
User
A central station has sent a system shutdown command to the panel
415
Dialer shutdown command received
User
A central station has sent a dialer shutdown command to the panel
416
Successful Upload
Zone
The configuration data of the system has been successfully uploaded
421
Access denied
User
The access control system has denied access to the specified user
422
Access report by user
User
423
Forced Access
User
The specified access control door has been forced open
424
Egress Denied
User
The access control system has denied egress to the specified user
425
Egress Granted
User
The access control system has granted egress for the specified user
426
Access Door propped open
Zone
The specified access control door has been held open
427
Access point Door Status Monitor trouble
Zone
The specified Access Point's Door Status Monitor has reported a trouble condition to the panel
428
Access point Request To Exit trouble
Zone
The specified Access Point's Request To Exit zone has reported a trouble condition to the panel
429
Access program mode entry
User
The access control system has been put into program mode
430
Access program mode exit
User
The access control system has exited program mode
431
Access threat level change
User
The access control system's threat level has been changed
432
Access relay/trigger fail
Zone
The specified access control output device has failed to operate properly
433
Access RTE shunt
Zone
The specified Request To Exit zone has been shunted and will no longer report activity
434
Access DSM shunt
Zone
The specified Door Status Monitor zone has been shunted and will no longer report activity
435
Second Person Access
User
A second person has accessed an access point conforming to Two-Man-Rule requirements
436
Irregular Access
User
441
Armed STAY
User
The specified user has armed the system in STAY mode
442
Keyswitch Armed STAY
User
The specified user has armed the system in STAY mode using a keyswitch
443
Armed with System Trouble Override
User
The specified user has armed the system while overriding a trouble condition
450
Exception O/C
User
The system has been armed or disarmed outside of the configured time window
451
Early O/C
User
The system has been disarmed/armed by the specified user before the configured time window has started
452
Late O/C
User
The system has been disarmed/armed by the specified user after the configured time window has ended
453
Failed to Open
User
The system has failed to have been disarmed during the designated time window
454
Failed to Close
User
The system has failed to be armed during the designated time window
455
Auto-arm Failed
User
The system has failed to automatically arm itself at the designated time
456
Partial Arm
User
The system has been only partially armed by the specified user
457
Exit Error (user)
User
The specified user has made an error exiting the premises after arming the system
458
User on Premises
User
A user has disarmed the system after an alarm has occurred
459
Recent Close
User
The system had been armed within the last xx minutes
461
Wrong Code Entry
Zone
462
Legal Code Entry
User
463
Re-arm after Alarm
User
464
Auto-arm Time Extended
Zone
A user has successfully requested that the system delay automatically arming
465
Panic Alarm Reset
User
The specified panic zone has been reset
466
Service On/Off Premises
User
A service person has entered or left the premises
501
Access reader disable
Zone
The credential reader on the specified access point has been disabled
520
Sounder/Relay Disable
Zone
The specified sounder or relay has been disabled
521
Bell 1 disable
Zone
The specified output for Bell 1 has been disabled
522
Bell 2 disable
Zone
The specified output for Bell 2 has been disabled
523
Alarm relay disable
Zone
The specified alarm relay has been disabled
524
Trouble relay disable
Zone
The specified trouble relay has been disabled
525
Reversing relay disable
Zone
The specified reversing relay has been disabled
526
Notification Appliance Ckt. # 3 disable
Zone
The specified output for Bell 3 has been disabled
527
Notification Appliance Ckt. # 4 disable
Zone
The specified output for Bell 4 has been disabled
531
Module Added
Zone
The specified access control module has been added to the system
532
Module Removed
Zone
The specified access control module has been removed from the system
551
Dialer disabled
Zone
The specified dialer has been disabled
552
Radio transmitter disabled
Zone
The specified radio transmitter has been disabled
553
Remote Upload/Download disabled
Zone
Remote configuration has been enabled
570
Zone/Sensor bypass
Zone
The specified zone or sensor has been bypassed
571
Fire bypass
Zone
The specified fire zone has been bypassed
572
24 Hour zone bypass
Zone
The specified 24 hour zone has been bypassed
573
Burg. Bypass
Zone
The specified burglary zone has been bypassed
574
Group bypass
Zone
A group of zones has been bypassed
575
Swinger bypass
Zone
The specified zone which has reported an excessive number of faults/restores in a short period of time has been bypassed
576
Access zone shunt
Zone
The specified zone in the access control system has been shunted and will no longer report activity
577
Access point bypass
Zone
The specified access point in the access control system has been bypassed and will allow the door to open (unsecured)
578
Vault Bypass
Zone
The specified vault zone has been bypassed
579
Vent Zone Bypass
Zone
The specified vent zone has been bypassed and will no longer report any activity
601
Manual trigger test report
Zone
A test report has been triggered manually
602
Periodic test report
Zone
A periodic test report has been triggered
603
Periodic RF transmission
Zone
A periodic RF path test report has been triggered
604
Fire test
User
The specified user has initiated a test of the fire alarm zones
605
Status report to follow
Zone
606
Listen-in to follow
Zone
The system is about to activate a 2-way audio session
607
Walk test mode
User
The specified user has placed the system into the walk-test mode for testing purposes
608
Periodic test - System Trouble Present
Zone
A periodic test has been triggered but the fire system has a trouble condition present
609
Video Xmitter active
Zone
A video look-in session is about to begin
611
Point tested OK
Zone
The specified point tested successfully
612
Point not tested
Zone
The specified point has not been tested
613
Intrusion Zone Walk Tested
Zone
The specified intrusion zone has been successfully walk-tested
614
Fire Zone Walk Tested
Zone
The specified fire zone has been successfully walk-tested
615
Panic Zone Walk Tested
Zone
The specified panic zone has been successfully walk-tested
616
Service Request
Zone
A request has been made for system servicing
621
Event Log reset
Zone
The event log has been reset and all stored events have been discarded
622
Event Log 50% full
Zone
The event log is 50% full
623
Event Log 90% full
Zone
The event log is 90% full
624
Event Log overflow
Zone
The event log has overflowed and events have been lost
625
Time/Date reset
User
The time and date have been reset to a new value by the specified user
626
Time/Date inaccurate
Zone
The system time and date is known to be in error
627
Program mode entry
Zone
The system has been placed into program mode
628
Program mode exit
Zone
The system has exited program mode
629
32 Hour Event log marker
Zone
630
Schedule change
Zone
The specified fire/burglary schedule has been changed
631
Exception schedule change
Zone
The time schedule for event reporting by exception has been changed
632
Access schedule change
Zone
The specified access control schedule has been changed
641
Senior Watch Trouble
Zone
A person has not activated a motion sensor in a specified period
642
Latch-key Supervision
User
A child has disarmed the system (after school)
651
Reserved for Ademco Use
Zone
652
Reserved for Ademco Use
User
653
Reserved for Ademco Use
User
654
System Inactivity
Zone
System has not been operated for x days
655
User Code X modified by Installer
User
The Installer has modified the specified User's code
703
Auxiliary #3
Zone
704
Installer Test
Zone
750
User Assigned
789
User Assigned
796
Unable to output signal (Derived Channel)
Zone
798
STU Controller down (Derived Channel)
Zone
900
Download Abort
Downloader ID
The specified Downloader ID has aborted a download sequence in progress
901
Download Start/End
Downloader ID
Downloader has started or ended a download sequence to the panel
902
Download Interrupted
Downloader ID
A download sequence has been interrupted
903
Device Flash Update Started/ Completed
Device
A code update for a device has started (E903) or completed successfully (R903)
904
Device Flash Update Failed
Device
A code update for a device has failed
910
Auto-close with Bypass
Zone
An auto-close sequence has been started and the specified zone has been bypassed
911
Bypass Closing
Zone
912
Fire Alarm Silence
Zone
The fire alarm has been silenced
913
Supervisory Point test Start/End
User
A fire supervisory device has been tested
914
Hold-up test Start/End
User
The specified user has started or ended a hold-up test
915
Burg. Test Print Start/End
User
The printed progress of a burglary test has been started or ended
916
Supervisory Test Print Start/End
User
The printed progress of a supervisory test has been started or ended
917
Burg. Diagnostics Start/End
Zone
A burglary system diagnostic test has been started or ended
918
Fire Diagnostics Start/End
Zone
A fire system diagnostic test has been started or ended
919
Untyped diagnostics
Zone
920
Trouble Closing (closed with burg. during exit)
User
921
Access Denied Code Unknown
User
Access has been denied because the system did not recognize the supplied access code as valid
922
Supervisory Point Alarm
Zone
The specified supervisory point has reported an alarm condition
923
Supervisory Point Bypass
Zone
The specified supervisory point has been bypassed
924
Supervisory Point Trouble
Zone
The specified supervisory point has reported a trouble condition
925
Hold-up Point Bypass
Zone
The specified hold-up point has been bypassed
926
AC Failure for 4 hours
Zone
There has been a loss of AC power for at least four hours
927
Output Trouble
Zone
The specified output has reported a trouble condition
928
User code for event
User
This message contains the ID of the user who triggered the previous event
929
Log-off
User
The specified user has logged-off of the system
954
CS Connection Failure
Zone
The specified CS connection has failed/restored
961
Rcvr Database Connection Fail/Restore
Zone
The connection to the receiver's database has failed/restored
962
License Expiration Notify
Zone
The product license has been terminated (7810PC)
Last updated
Was this helpful?