T20 firmware upgrade fails
Resolve failed T20 firmware upgrades from version 1.x to version 4.x or later.
Symptoms and cause
Symptom: Errors appear in the Connections tab of the T20, or in the Alarm Viewer, when attempting a firmware upgrade.


Cause: The T20 firmware is on version 1.xxx, and the target firmware is version 4.xx or higher. Direct upgrade from 1.x to 4.x is not supported.
Affected terminals
T20 readers are affected if they have always used CardaxIV. Their serial number is older than 1420xxxxxxxx.
Resolution
Take the T20 reader to a system running Command Centre version 7.20 to 7.60.
Connect the reader to that system.
Upgrade the firmware to version 3.x on that system.
Return the reader to the original site.
Reconnect and proceed with the upgrade to 4.x or higher.
The intermediate step via a 7.20 to 7.60 system is mandatory when the reader has never been updated past firmware 1.x. The reader cannot bridge the major version gap in a single upgrade pass.
🔗 Related
T Series - T20 User Guide and Resolution. The T20 terminal.
T Series - Non HBUS compatible. Older CardaxIV-only readers.
Last updated
Was this helpful?