View alarm zones and inputs

View alarm zones and inputs on a Gallagher T20 Terminal, and shunt an input.

Alarm zones

Log on and choose Alarm Zones from the Menu. The screen lists the alarm zones assigned to the terminal. The symbol to the right of each shows its last known state. Arm and disarm from here: see Arm alarm zones and Disarm alarm zones.

Inputs

You need the View alarms and items privilege to view inputs.

  1. Choose Inputs from the Menu.

  2. The Inputs screen lists the inputs assigned to the terminal in the alarm zones you hold View alarms and items for. A T20 Alarms Terminal can control up to 100 inputs.

Shunted, tampered, isolated and offline inputs are listed first, alphabetically. The word to the right of each input shows its last known state: Open, Closed, Shunted, Tamper break, Tamper short, Isolated (open, closed, tamper break, tamper short or offline) or Offline.

Shunt or isolate an input

You need the Shunt items or Auto-isolate alarm zones privilege for the input's alarm zone.

  1. Select the input and press Options. The Input Options screen displays.

  2. Select Shunt or Isolate and press Select.

A shunted input does not report status or events. An isolated input does not report events until its alarm zone is next disarmed, or until it is de-isolated.