> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/products/cc-hardware/perimeter-solutions/perimeter-keypads/configure/keypads-remote-arming-terminal-operati.md). Agents can also search and read this documentation through its [MCP server](https://help.security.gallagher.com/knowledge-hub/~gitbook/mcp).

# Operate a T20 Terminal

The keys, screens, status lights and privileges behind every task at a Gallagher T20 Terminal.

This page covers the fundamentals of a Gallagher T20 Terminal: the models, how it connects, where its privileges come from, and the keys, screens and lights you work with. Each task (signing in, arming, fence zones, alarms, testing) has its own page in this section.

### Models

| Part #            | Product                 | Use                                                                 |
| ----------------- | ----------------------- | ------------------------------------------------------------------- |
| C300450 / C300451 | T20 MIFARE Terminal     | Card reader for a door, plus alarm and fence zone management.       |
| C300460 / C300461 | T20 Multi Tech Terminal | As above, plus Gallagher mobile credentials over Bluetooth.         |
| C300463 / C300464 | T20 Alarms Terminal     | Alarm and fence zone management only. No card reader, no Bluetooth. |

### Connection

* The terminal connects to a **Gallagher Controller 7000** over HBUS. A terminal used for alarm management must be connected as an HBUS device. The T20 Alarms Terminal is HBUS only.
* Fence zones appear on a terminal only after, in the terminal's properties in Command Centre, the fence zone's alarm zone is added on the **Alarm Zones** tab and its fence controller on the **Fence Controllers** tab. One terminal can control up to 25 fence controllers, or 50 fence zones.

### Privileges

What a cardholder can do at the terminal comes from the privileges of their **Access Group**, set for each alarm zone the Access Group lists. The privileges that matter for perimeter work are:

* Change to the Armed state, and Change to the Disarmed state.
* Change fence to HV/LF mode.
* View alarms and items. Needed to view alarms, inputs and fence controllers, and to change a fence zone's state.
* Acknowledge all alarms, and Acknowledge alarms below high priority.
* Shunt items.
* Lock out fence zones. Needed to start a lockout.
* Cancel others lockout. Lets a supervisor cancel someone else's lockout, at the terminal that started it.

### Keys

| Key            | Use                                                                                                                                 |
| -------------- | ----------------------------------------------------------------------------------------------------------------------------------- |
| Soft keys      | Their labels show at the bottom of the screen and change with the screen, for example **More**, **Arm**, **Arm All** or **Select**. |
| Arrow keys     | Scroll the Menu, the Options Menu and lists. The up arrow below the screen opens the Menu or Options Menu.                          |
| **✓** (tick)   | Make a selection, and confirm a user code or PIN.                                                                                   |
| **Back** (red) | Go back one screen. Press it until the Welcome screen displays, or hold it for more than 1 second, to log off.                      |
| **0–9**        | Type a user code or PIN, or select the item with that number.                                                                       |
| **\***         | Show the Mimic Panel, if one is set up.                                                                                             |
| **#**          | Press and hold for 3 seconds to show the Information screen.                                                                        |

### Screens

* **Welcome screen.** The home screen. It shows the date and time, and tells you what the terminal expects, for example **Card or Code**.
* **Menu.** Appears after you log on. What it lists depends on your Command Centre privileges, for example Alarm Zones, Alarms, Inputs, Fences, Actions and Test. **Actions** lists the outputs you can trigger. Its name can be changed in Command Centre.
* **Options Menu.** Where the Welcome screen shows **Options**, it opens a menu that needs no logon. It includes **View the menu**, and lists up to 5 outputs that anyone at the terminal can trigger. An output shows there only if its alarm zone is assigned to the terminal.
* **Information screen.** Hold **#** for 3 seconds to see the terminal's software versions and, on a model with a card reader, the card technologies it supports.
* **Backlight.** The screen dims after 30 seconds without use and turns off after 30 minutes. From Command Centre vEL7.30, the **Always on** setting stops the screen turning off. It still dims after 30 seconds.

{% hint style="warning" %}
Anyone at the terminal can trigger the outputs on the Options Menu without logging on.
{% endhint %}

### Status light

| Light                  | Meaning                                                                                            |
| ---------------------- | -------------------------------------------------------------------------------------------------- |
| Four rapid red flashes | The controller the terminal is connected to is upgrading.                                          |
| Three amber flashes    | No communication with the controller. The screen shows **Connecting...**                           |
| Two amber flashes      | Communicating, but not configured. The screen shows **Not configured**.                            |
| One amber flash        | Configured, but no door, elevator car or alarm zone assigned. The screen shows **Not configured**. |

Once the terminal is fully configured, the T20 Alarms Terminal shows solid green while a user is logged on and solid red when logged off. A T20 Terminal running a door shows solid green when the door's access mode is Free and solid red when it is Secure.

***

🔗 **Related**

* [Sign in to a T20 Terminal](https://help.security.gallagher.com/knowledge-hub/products/cc-hardware/perimeter-solutions/perimeter-keypads/configure/keypads-logging-on.md). How to log on.
* [Arm alarm zones](https://help.security.gallagher.com/knowledge-hub/products/cc-hardware/perimeter-solutions/perimeter-keypads/configure/keypads-arming.md) · [Disarm alarm zones](https://help.security.gallagher.com/knowledge-hub/products/cc-hardware/perimeter-solutions/perimeter-keypads/configure/keypads-disarming.md). Change alarm zone state at the terminal.
* [View and acknowledge alarms](https://help.security.gallagher.com/knowledge-hub/products/cc-hardware/perimeter-solutions/perimeter-keypads/configure/keypads-viewing-and-acknowledging-alar.md). Handle alarms from the terminal.
* [Use a T20 Terminal at a door](https://help.security.gallagher.com/knowledge-hub/products/cc-hardware/perimeter-solutions/perimeter-keypads/configure/keypads-remote-arming-terminal-as-a-ke.md). Door access.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/products/cc-hardware/perimeter-solutions/perimeter-keypads/configure/keypads-remote-arming-terminal-operati.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.