Change alarm zone voltage mode
Change all compatible fence zones within an alarm zone between high voltage and Low Feel modes.
📎 Compatibility: Low Feel mode is available on every Gallagher energizer.
📎 Compatibility: Command Centre controls HV/LF mode on F3x, F4x, F5x and F6x fence controllers.
On the T20, voltage mode is an action on each fence zone.
Change every fence zone in an alarm zone
Repeat Change fence zone voltage mode for each fence zone in the alarm zone. You need the View alarms and items and Change fence to HV/LF mode privileges for the alarm zone. Each change is an On override, so each of those fence zones pulses, and stays that way until someone cancels its override, even if the alarm zone is disarmed. Treat them as live.
Change them on a regular pattern
Use the alarm zone's HV/LF schedule in Command Centre instead. For example, a schedule can run Low Feel from 07:00 and high voltage from 17:00 on weekdays. A fence zone can be armed in either mode.
🔗 Related
Change fence zone voltage mode. The procedure for one fence zone.
Monitor fence zone status. Check each zone's mode.