Change fence zone voltage mode
Change a compatible fence zone between high voltage and Low Feel modes.
📎 Compatibility: Low Feel mode is available on every Gallagher energizer.
📎 Compatibility: Command Centre controls HV/LF mode on F3x, F4x, F5x and F6x fence controllers.
Required privileges: View alarms and items and Change fence to HV/LF mode, for the fence zone's alarm zone.
A fence zone takes its HV/LF mode from its alarm zone, which can follow an HV/LF schedule set in Command Centre. A change made at the terminal is an override, and stays in place until someone cancels it.
Procedure
Log on. If the fence controller list isn't showing, choose Fences from the Menu.
Select the fence controller and press More.
Select the fence zone and press More. The details show the zone's current state.
Choose Override to On - Low Feel or Override to On - High Voltage, and press Select.
To cancel the override, open the same fence zone and choose Cancel overrides. The fence zone then follows its alarm zone again, so it stays live if the alarm zone is armed.
🔗 Related
Change alarm zone voltage mode. Changing every fence zone in an alarm zone.
Monitor fence zone voltages. Check the result.
Last updated