Perimeter terminals
Learn which Gallagher terminal controls a perimeter system, and what an operator can do from it.
The Gallagher T20 Terminal is how an operator works with alarm zones and fence zones at the fence line. From a T20 you log on, arm and disarm alarm zones, change fence zone voltage mode, lock a fence zone out so it can be worked on safely, and view and acknowledge alarms.
The terminal does not make access decisions. It sends information to the Gallagher controller and acts on information the controller sends back.
Which terminal
C300463
T20 Alarms Terminal, black
Alarm and fence zone management. Cannot read cards.
C300464
T20 Alarms Terminal, white
Alarm and fence zone management. Cannot read cards.
C300450 / C300451
T20 Terminal, MIFARE
Card reader, plus alarm and fence zone management.
C300460 / C300461
T20 Terminal, Multi Tech
Card reader with mobile credentials over BLE, plus zone management.
The T20 works with F3x, F4x, F5x and F6x fence controllers in network control. Fence zone management is supported from vHT4.0 (Command Centre vEL7.40); F5x/F6x need vEL9.40 or later.
Capacities and supply
A T20 Terminal can control up to 25 fence controllers, or 50 fence zones.
Supply voltage range 9–16 V DC measured at the terminal's own terminals. Approximately 12 V DC is recommended.
Operating current depends on the supply voltage at the terminal.
What you can do from a terminal
Log on with a card, a card and PIN, or a user code
Arm all or selected alarm zones
Disarm an alarm zone
Lock a fence zone out so it can be worked on
Switch a fence zone between high voltage and Low Feel
View battery and fence zone voltages
View current and seven-day controller temperature
View fence controller and fence zone states
Override, shunt or lock out a fence zone
View alarm zones and inputs, and shunt an input
View and acknowledge alarms
See where each kind of status is shown
Test alarm inputs
Use a card-reader T20 at a door
A lockout can be started only at a terminal, and canceled only at the terminal that started it. Neither can be done from a Command Centre workstation.
🔗 Related
Energizers. The fence controllers a terminal arms and monitors.
Perimeter intrusion detection. The sensors that raise the alarms a terminal shows.
Last updated
Was this helpful?