Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

Perimeter terminals

Learn which Gallagher terminal controls a perimeter system, and what an operator can do from it.

The Gallagher T20 Terminal is how an operator works with alarm zones and fence zones at the fence line. From a T20 you log on, arm and disarm alarm zones, change fence zone voltage mode, lock a fence zone out so it can be worked on safely, and view and acknowledge alarms.

The terminal does not make access decisions. It sends information to the Gallagher controller and acts on information the controller sends back.

Which terminal

Part #
Product
Use

C300463

T20 Alarms Terminal, black

Alarm and fence zone management. Cannot read cards.

C300464

T20 Alarms Terminal, white

Alarm and fence zone management. Cannot read cards.

C300450 / C300451

T20 Terminal, MIFARE

Card reader, plus alarm and fence zone management.

C300460 / C300461

T20 Terminal, Multi Tech

Card reader with mobile credentials over BLE, plus zone management.

The T20 works with F3x, F4x, F5x and F6x fence controllers in network control. Fence zone management is supported from vHT4.0 (Command Centre vEL7.40); F5x/F6x need vEL9.40 or later.

Capacities and supply

  • A T20 Terminal can control up to 25 fence controllers, or 50 fence zones.

  • Supply voltage range 9–16 V DC measured at the terminal's own terminals. Approximately 12 V DC is recommended.

  • Operating current depends on the supply voltage at the terminal.

What you can do from a terminal

Task
Page

Log on with a card, a card and PIN, or a user code

Arm all or selected alarm zones

Disarm an alarm zone

Lock a fence zone out so it can be worked on

Switch a fence zone between high voltage and Low Feel

View battery and fence zone voltages

View current and seven-day controller temperature

View fence controller and fence zone states

Override, shunt or lock out a fence zone

View alarm zones and inputs, and shunt an input

View and acknowledge alarms

See where each kind of status is shown

Test alarm inputs

Use a card-reader T20 at a door

A lockout can be started only at a terminal, and canceled only at the terminal that started it. Neither can be done from a Command Centre workstation.


🔗 Related