For the complete documentation index, see llms.txt. This page is also available as Markdown.

Connect Fibre Transceiver power and ground

Learn how to power, ground, and electrically isolate Gallagher Fibre Transceivers.

Connect each Fibre Transceiver to a suitable power supply and a common ground. Isolate the unit from metallic surfaces.

Connect power and ground

Use the same power supply provided to the connected controller. A Fence Controller can power its connected Fibre Transceiver.

Connect the transceiver power negative to the HBUS device negative, or 0 V. Devices that use separate supplies must share a common ground.

Connect 0 V from the Controller 6000 to the Fibre Transceiver. Connect 0 V from the Fibre Transceiver to its HBUS devices.

Power each N12 from its connected Fence Controller. Battery-backed Fence Controllers provide a stable transceiver power supply.

Isolate the unit

Electrically isolate the Fibre Transceiver from metallic surfaces.

Use isolation part G28813 with N11 and N12 units. It is supplied in packs of 10.