Energizers

Reference F-Series energizer models, capacities, installation limits, accessories, and conformity documents.

Monitored Pulse Fence (MPF) energizers produce regulated safe high-voltage pulses on the fence, detect intrusion by monitoring voltage drop, arm and disarm zones, and communicate alarms. They can be online with Command Centre or standalone, depending on site requirements.

Gallagher fence with energizer lead-outs installed on a perimeter fence

🧭 Where to start

  • Specifying a new fence? Start with the current F5x/F6x range in Key specs and Variants.

  • Working on an existing site? The legacy F3x/F4x part numbers are in Variants.

  • Ordering accessories? Go to Accessories.

  • Need a declaration of conformity? Go to Certificates.

Key specifications

The current range is F51, F52, F61 and F62. F51 and F52 are the standard 2.3 J / 8 kV models. F61 and F62 also run at 2.3 J / 8 kV, and step up to HV+ (3.6 J, around 10 kV) for 20 minutes when an attack is detected.

Model
Part #
Zones
Operation
Max Output
Battery

F51

G21923

1

Standalone or HBUS

2.3J / 8kV

12V 7Ah, not supplied

F52

G21943

2

Standalone or HBUS

2.3J / 8kV

12V 7Ah, not supplied

F61

G21933

1

Standalone or HBUS

3.6J / 10kV (HV+)

12V 7Ah, not supplied

F62

G21953

2

Standalone or HBUS

3.6J / 10kV (HV+)

12V 7Ah, not supplied

F61-EN

G21935

1

Standalone or HBUS

8kV, HV+ not available

12V 7Ah, not supplied

F62-EN

G21955

2

Standalone or HBUS

8kV, HV+ not available

12V 7Ah, not supplied

F61-EN and F62-EN are the EN variants of F61 and F62, with HV+ removed.

F52 and F62 fence controllers

Key features

  • On-board status display. It does not show a lockout set from a terminal: check the fence zone on the terminal before touching the fence.

  • Service mode, entered with SW1 dipswitch 1. (SW1 dipswitch 9 is a different switch: it selects HBUS or Standalone mode.) In HBUS mode, Command Centre must also allow Service mode. In Service mode the magnetic key (G21963, one supplied with the controller) arms and disarms each fence zone locally, except zones in Lockout. When Service mode ends, the fence zones go straight back to the state Command Centre or the inputs set, so treat the fence as live.

  • Smart Sync, Gallagher's synchronization protocol. Before F5x/F6x join a site running F3x/F4x, update the F3x/F4x firmware to Smart Sync.

  • HV+ escalation mode on F61 and F62 only. It increases voltage on alarm.

  • SELV Ready on F61 and F62 only. Not yet available — it arrives in a later software update, so do not design against it today.

  • Low Feel mode, a reduced output (0.9 kV per channel without load by default), selected by input IN2 in Standalone mode or from Command Centre. The fence stays energized and delivers an unpleasant but tolerable pulse.

  • Battery backup with an auto-test every 14 days.

  • Temperature management. Pulsing stops when the internal temperature reaches 85°C, about 62°C ambient in landscape orientation and 51°C in portrait.

  • HBUS connection to Command Centre. A Controller 7000 is required, and HBUS support requires Command Centre vEL9.40 or later.

Installation limits

  • Maximum HBUS cable run is 500 m from the Controller 7000.

  • Maximum 24 F-series fence controllers per Controller 7000.

  • Up to 100 F5x/F6x on one LV Sync bus, over up to 1.2 km. For more than 100, chain LV Sync buses with Internal HV Sync, with an F52 or F62 as each bus's primary, up to 250 controllers on a site.

  • HV sync is available on F52 and F62 only.

  • Mount the energizer close to the fence to minimize lead-out cable length.

  • Segregate HV, mains and data cabling. Minimum separation is 300 mm.

Alarm outputs

These are the Standalone mode functions. In HBUS mode, outputs are configured in Command Centre.

Output
Function

Out1

System alarm (battery, tamper, temp, sync loss)

Out2

Power failure

Out3

Zone (-Ve) alarm

Out4

Armed indication

Out5

Zone (+Ve) alarm, F52 and F62 only

Variants

F5x/F6x controllers used with Command Centre, and HBUS connection to a Controller 7000, need Command Centre vEL9.40 or later. The F3x/F4x generation has been supported since vEL7.40.

Current, F5x / F6x (Smart Sync; Command Centre vEL9.40 or later when networked)

Part #
Model
Description

G21923

F51

Single Zone Energizer (2.3 J / 8 kV)

G21943

F52

Dual Zone Energizer (2.3 J / 8 kV)

G21933

F61

Single Zone HV+ Energizer (3.6 J / 10 kV)

G21935

F61-EN

EN 60335-2-76 variant

G21953

F62

Dual Zone HV+ Energizer (3.6 J / 10 kV)

G21955

F62-EN

EN 60335-2-76 variant

Legacy, F3x / F4x (supported from vEL7.40)

Part #
Model
Description

G21920

F31

Single Zone Energizer

G21921

F31, Canada Variant

Single Zone Energizer (Canada)

G21922

F31, Apave Variant

Single Zone Energizer (Apave)

G21940

F32

Dual Zone Energizer

G21941

F32, Canada Variant

Dual Zone Energizer (Canada)

G21942

F32, Apave Variant

Dual Zone Energizer (Apave)

G21930

F41

Single Zone HV+ Energizer

G21931

F41, Canada Variant

Single Zone HV+ Energizer (Canada)

G21932

F41, Apave Variant

Single Zone HV+ Energizer (Apave)

G21950

F42

Dual Zone HV+ Energizer

G21951

F42, Canada Variant

Dual Zone HV+ Energizer (Canada)

Variant status

Variant
Status
Introduced in
Relationship
Coexistence

F31 / F32 / F41 / F42

Legacy, being replaced

vEL7.40

Predecessor of F5x/F6x

Can share a site once updated to Smart Sync, as LV Sync secondaries

F51 / F52

Current

vEL9.40

Replaces F31 / F32

See upgrade path below

F61 / F62

Current

vEL9.40

Replaces F41 / F42

See upgrade path below; HV+ class

F61-EN / F62-EN

Current, EN variant

vEL9.40

EN variant of F61/F62

Without HV+, for EN / BS EN limits

Upgrade path. Before adding F5x/F6x to a site running F3x/F4x, update the F3x/F4x firmware to Smart Sync, on Command Centre 9.40 MR or later, and make an F5x/F6x the LV Sync primary with the F3x/F4x as secondaries (3E6034, Permitted Installation Scenarios). F61 and F62 are Type S energizers and must not be used in a Type R energizer group; F51, F52 and the EN variants are Type R.

Accessories

Part Number
Product Name
Description

G21963

Magnetic Key

Service mode at the controller. One is included with every Fence Controller — order only as a spare.

G21965

F-Series Cable Manager

For use in managing HV cabling at the energizer

G21961

Power Supply 15 V 2.4 A

100–240 VAC, 15 VDC 2.4 A. Fitted to F31/F32 and some F41/F42 controllers — order only as a spare or replacement.

G21962

Power Supply 15 V 4.0 A

100–240 VAC, 15 VDC 4.0 A. Fitted to some F41/F42 controllers — order only as a spare or replacement. F5x/F6x ship with power supply G21964 fitted.

Certificates

Declarations of conformity and test reports:

Document Type
Document

AS/NZS Supplier Declaration of Conformity

F5x F6x RCM DoC 2026-02-24

EU CE Declaration of Conformity

F5x F6x CE DoC 2026-01-30

UK CA Declaration of Conformity

F5x F6x UKCA DoC 2026-01-30

AS/NZS RCM Electrical Safety Certificate of Conformity

F5x F6x SAFETY AUS NZ 2026-02-27 to 2031-02-27 (incl. MK PSU)

USA FCC Declaration of Conformity

F5x F6x FCC DoC 2026-01-30

Test Lab report front page

F5x F6x Test Report front page 2025-11-11

The RCM safety certificate and the test report are public:

The CE, UKCA and FCC declarations are held in Gallagher Compliance.