Energizers
Reference F-Series energizer models, capacities, installation limits, accessories, and conformity documents.
Monitored Pulse Fence (MPF) energizers produce regulated safe high-voltage pulses on the fence, detect intrusion by monitoring voltage drop, arm and disarm zones, and communicate alarms. They can be online with Command Centre or standalone, depending on site requirements.

🧭 Where to start
Working on an existing site? The legacy F3x/F4x part numbers are in Variants.
Ordering accessories? Go to Accessories.
Need a declaration of conformity? Go to Certificates.
Key specifications
The current range is F51, F52, F61 and F62. F51 and F52 are the standard 2.3 J / 8 kV models. F61 and F62 also run at 2.3 J / 8 kV, and step up to HV+ (3.6 J, around 10 kV) for 20 minutes when an attack is detected.
F51
G21923
1
Standalone or HBUS
2.3J / 8kV
12V 7Ah, not supplied
F52
G21943
2
Standalone or HBUS
2.3J / 8kV
12V 7Ah, not supplied
F61
G21933
1
Standalone or HBUS
3.6J / 10kV (HV+)
12V 7Ah, not supplied
F62
G21953
2
Standalone or HBUS
3.6J / 10kV (HV+)
12V 7Ah, not supplied
F61-EN
G21935
1
Standalone or HBUS
8kV, HV+ not available
12V 7Ah, not supplied
F62-EN
G21955
2
Standalone or HBUS
8kV, HV+ not available
12V 7Ah, not supplied
F61-EN and F62-EN are the EN variants of F61 and F62, with HV+ removed.

Key features
On-board status display. It does not show a lockout set from a terminal: check the fence zone on the terminal before touching the fence.
Service mode, entered with SW1 dipswitch 1. (SW1 dipswitch 9 is a different switch: it selects HBUS or Standalone mode.) In HBUS mode, Command Centre must also allow Service mode. In Service mode the magnetic key (G21963, one supplied with the controller) arms and disarms each fence zone locally, except zones in Lockout. When Service mode ends, the fence zones go straight back to the state Command Centre or the inputs set, so treat the fence as live.
Smart Sync, Gallagher's synchronization protocol. Before F5x/F6x join a site running F3x/F4x, update the F3x/F4x firmware to Smart Sync.
HV+ escalation mode on F61 and F62 only. It increases voltage on alarm.
SELV Ready on F61 and F62 only. Not yet available — it arrives in a later software update, so do not design against it today.
Low Feel mode, a reduced output (0.9 kV per channel without load by default), selected by input IN2 in Standalone mode or from Command Centre. The fence stays energized and delivers an unpleasant but tolerable pulse.
Battery backup with an auto-test every 14 days.
Temperature management. Pulsing stops when the internal temperature reaches 85°C, about 62°C ambient in landscape orientation and 51°C in portrait.
HBUS connection to Command Centre. A Controller 7000 is required, and HBUS support requires Command Centre vEL9.40 or later.
Installation limits
Maximum HBUS cable run is 500 m from the Controller 7000.
Maximum 24 F-series fence controllers per Controller 7000.
Up to 100 F5x/F6x on one LV Sync bus, over up to 1.2 km. For more than 100, chain LV Sync buses with Internal HV Sync, with an F52 or F62 as each bus's primary, up to 250 controllers on a site.
HV sync is available on F52 and F62 only.
Mount the energizer close to the fence to minimize lead-out cable length.
Segregate HV, mains and data cabling. Minimum separation is 300 mm.
Alarm outputs
These are the Standalone mode functions. In HBUS mode, outputs are configured in Command Centre.
Out1
System alarm (battery, tamper, temp, sync loss)
Out2
Power failure
Out3
Zone (-Ve) alarm
Out4
Armed indication
Out5
Zone (+Ve) alarm, F52 and F62 only
Variants
F5x/F6x controllers used with Command Centre, and HBUS connection to a Controller 7000, need Command Centre vEL9.40 or later. The F3x/F4x generation has been supported since vEL7.40.
Current, F5x / F6x (Smart Sync; Command Centre vEL9.40 or later when networked)
G21923
F51
Single Zone Energizer (2.3 J / 8 kV)
G21943
F52
Dual Zone Energizer (2.3 J / 8 kV)
G21933
F61
Single Zone HV+ Energizer (3.6 J / 10 kV)
G21935
F61-EN
EN 60335-2-76 variant
G21953
F62
Dual Zone HV+ Energizer (3.6 J / 10 kV)
G21955
F62-EN
EN 60335-2-76 variant
Legacy, F3x / F4x (supported from vEL7.40)
G21920
F31
Single Zone Energizer
G21921
F31, Canada Variant
Single Zone Energizer (Canada)
G21922
F31, Apave Variant
Single Zone Energizer (Apave)
G21940
F32
Dual Zone Energizer
G21941
F32, Canada Variant
Dual Zone Energizer (Canada)
G21942
F32, Apave Variant
Dual Zone Energizer (Apave)
G21930
F41
Single Zone HV+ Energizer
G21931
F41, Canada Variant
Single Zone HV+ Energizer (Canada)
G21932
F41, Apave Variant
Single Zone HV+ Energizer (Apave)
G21950
F42
Dual Zone HV+ Energizer
G21951
F42, Canada Variant
Dual Zone HV+ Energizer (Canada)
Variant status
F31 / F32 / F41 / F42
Legacy, being replaced
vEL7.40
Predecessor of F5x/F6x
Can share a site once updated to Smart Sync, as LV Sync secondaries
F51 / F52
Current
vEL9.40
Replaces F31 / F32
See upgrade path below
F61 / F62
Current
vEL9.40
Replaces F41 / F42
See upgrade path below; HV+ class
F61-EN / F62-EN
Current, EN variant
vEL9.40
EN variant of F61/F62
Without HV+, for EN / BS EN limits
Upgrade path. Before adding F5x/F6x to a site running F3x/F4x, update the F3x/F4x firmware to Smart Sync, on Command Centre 9.40 MR or later, and make an F5x/F6x the LV Sync primary with the F3x/F4x as secondaries (3E6034, Permitted Installation Scenarios). F61 and F62 are Type S energizers and must not be used in a Type R energizer group; F51, F52 and the EN variants are Type R.
Accessories
G21963
Magnetic Key
Service mode at the controller. One is included with every Fence Controller — order only as a spare.
G21965
F-Series Cable Manager
For use in managing HV cabling at the energizer
G21961
Power Supply 15 V 2.4 A
100–240 VAC, 15 VDC 2.4 A. Fitted to F31/F32 and some F41/F42 controllers — order only as a spare or replacement.
G21962
Power Supply 15 V 4.0 A
100–240 VAC, 15 VDC 4.0 A. Fitted to some F41/F42 controllers — order only as a spare or replacement. F5x/F6x ship with power supply G21964 fitted.
Certificates
Declarations of conformity and test reports:
AS/NZS Supplier Declaration of Conformity
F5x F6x RCM DoC 2026-02-24
EU CE Declaration of Conformity
F5x F6x CE DoC 2026-01-30
UK CA Declaration of Conformity
F5x F6x UKCA DoC 2026-01-30
AS/NZS RCM Electrical Safety Certificate of Conformity
F5x F6x SAFETY AUS NZ 2026-02-27 to 2031-02-27 (incl. MK PSU)
USA FCC Declaration of Conformity
F5x F6x FCC DoC 2026-01-30
Test Lab report front page
F5x F6x Test Report front page 2025-11-11
The RCM safety certificate and the test report are public:
The CE, UKCA and FCC declarations are held in Gallagher Compliance.
🔗 Related
Fence Hardware. The posts, insulators, tensioning hardware and wire that make up the fence line.
Perimeter Keypads. Arming, disarming and monitoring the fence zones an energizer drives.
Controller 7000. The controller the energizer connects to over HBUS.
Last updated
Was this helpful?
