> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/deployment-resources/security-and-compliance/perimeter-fence-compliance/critical-distances-reference.md). Agents can also search and read this documentation through its [MCP server](https://help.security.gallagher.com/knowledge-hub/~gitbook/mcp).

# Critical Distances Reference

Check required clearances between pulse fences, barriers, power lines, and hostile toppings.

### This page answers

* What separation is required between the pulse fence and a physical barrier?
* What are the market-specific barrier rules?
* What clearances apply near power lines and hostile toppings?

### Attached Fence (to physical barrier)

* Openings in the physical barrier should have at least one dimension of 130mm (5in) or less.
* Separation depends on the market rule below. Where no standard is specified: 100mm to 200mm (4in to 7-13/16in), or a minimum of 1000mm (40in).
* Where an attached or free-standing barrier has **no openings**: maximum 200mm (7-13/16in) or minimum 1000mm (40in)

#### Market-Specific Barrier Rules (INTCOP 4.5)

| Market             | Standard    | Rule                                                                                                                               |
| ------------------ | ----------- | ---------------------------------------------------------------------------------------------------------------------------------- |
| UK (Palisade)      | BS1722-17   | 100 to 200mm (4 to 7-13/16in) separation, or 1000mm (40in) min where at least one dimension of each opening is 130mm (5in) or less |
| NZ/AU (Chain Mesh) | AS/NZS 3016 | 1000mm (40in) min where every dimension of an opening is over 54mm (about 2in)                                                     |
| Non-specified      | —           | 100 to 200mm (4 to 7-13/16in) separation, or 1000mm (40in) min                                                                     |

{% hint style="info" %}
When selecting barrier type, consider the likely presence of young children. This affects acceptable opening sizes.
{% endhint %}

### Free-standing pulse fence

* Minimum 1000mm (40in) from the physical barrier (INTCOP 7.1 Figure 2)
* Prohibited zone: energised conductors shall not be installed within the prohibited zone (the triangular zone on the public side of the physical barrier, see INTCOP 7.1 Figure 1)

### Horizontal Separation (independent energisers)

* Minimum 2.5m between uninsulated pulsed conductors from different unsynchronised energisers

### Vertical Separation

* Minimum 2m between pulsed conductors from different unsynchronised energisers

### Power Lines

| Voltage            | Min separation |
| ------------------ | -------------- |
| 1000V or less      | 3m (9ft 11in)  |
| Over 1000V to 33kV | 4m (13ft 2in)  |
| Over 33kV          | 8m (26ft 3in)  |

#### Near Overhead Power Lines (INTCOP 4.5.1)

* Fence conductors **should not** be mounted on overhead power-line support structures
* Where crossing overhead uninsulated power lines is unavoidable: cross underneath the lines, as close as possible to a right angle
* Connecting leads and fence wires near an overhead power line shall not exceed **3m (9ft 10in)** above ground
* This height limit applies within the orthogonal projection of the outermost power conductors for a distance of:
  * **2m (6ft 7in)** for power lines 1000V or less
  * **15m (49ft 3in)** for power lines over 1000V
* Where a fence passes below **bare** power conductors: the highest metallic element shall be earthed for **not less than 5m (16ft 5in)** on either side of the crossing point

### Barbed / Razor Wire Proximity

* Energised barbed or razor wire is **prohibited**
* Non-energized barbed or razor wire near an energized fence: minimum **1m (3ft 4in)** horizontal reach distance to prevent simultaneous contact with both

***

🔗 **Related**

* International Code of Practice (INTCOP 7.1) · Warning Sign Requirements


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/deployment-resources/security-and-compliance/perimeter-fence-compliance/critical-distances-reference.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.