Critical Distances Reference

Check required clearances between pulse fences, barriers, power lines, and hostile toppings.

This page answers

  • What separation is required between the pulse fence and a physical barrier?

  • What are the market-specific barrier rules?

  • What clearances apply near power lines and hostile toppings?

Attached Fence (to physical barrier)

  • Openings in the physical barrier should have at least one dimension of 130mm (5in) or less.

  • Separation depends on the market rule below. Where no standard is specified: 100mm to 200mm (4in to 7-13/16in), or a minimum of 1000mm (40in).

  • Where an attached or free-standing barrier has no openings: maximum 200mm (7-13/16in) or minimum 1000mm (40in)

Market-Specific Barrier Rules (INTCOP 4.5)

Market
Standard
Rule

UK (Palisade)

BS1722-17

100 to 200mm (4 to 7-13/16in) separation, or 1000mm (40in) min where at least one dimension of each opening is 130mm (5in) or less

NZ/AU (Chain Mesh)

AS/NZS 3016

1000mm (40in) min where every dimension of an opening is over 54mm (about 2in)

Non-specified

—

100 to 200mm (4 to 7-13/16in) separation, or 1000mm (40in) min

When selecting barrier type, consider the likely presence of young children. This affects acceptable opening sizes.

Free-standing pulse fence

  • Minimum 1000mm (40in) from the physical barrier (INTCOP 7.1 Figure 2)

  • Prohibited zone: energised conductors shall not be installed within the prohibited zone (the triangular zone on the public side of the physical barrier, see INTCOP 7.1 Figure 1)

Horizontal Separation (independent energisers)

  • Minimum 2.5m between uninsulated pulsed conductors from different unsynchronised energisers

Vertical Separation

  • Minimum 2m between pulsed conductors from different unsynchronised energisers

Power Lines

Voltage
Min separation

1000V or less

3m (9ft 11in)

Over 1000V to 33kV

4m (13ft 2in)

Over 33kV

8m (26ft 3in)

Near Overhead Power Lines (INTCOP 4.5.1)

  • Fence conductors should not be mounted on overhead power-line support structures

  • Where crossing overhead uninsulated power lines is unavoidable: cross underneath the lines, as close as possible to a right angle

  • Connecting leads and fence wires near an overhead power line shall not exceed 3m (9ft 10in) above ground

  • This height limit applies within the orthogonal projection of the outermost power conductors for a distance of:

    • 2m (6ft 7in) for power lines 1000V or less

    • 15m (49ft 3in) for power lines over 1000V

  • Where a fence passes below bare power conductors: the highest metallic element shall be earthed for not less than 5m (16ft 5in) on either side of the crossing point

Barbed / Razor Wire Proximity

  • Energised barbed or razor wire is prohibited

  • Non-energized barbed or razor wire near an energized fence: minimum 1m (3ft 4in) horizontal reach distance to prevent simultaneous contact with both