> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/services-and-workstations/creating-a-new-workstation-item.md).

# Creating a new Workstation Item

### Introduction

This procedure enables you to create a new Workstation Item.

**Note:**

Only Workstations can be created manually, (i.e. Services cannot be created manually. Instead, Command Centre creates them automatically whenever a new Service is detected).

***

### Configuration

To configure a new Workstation item, perform the following procedures in Gallagher Configuration Client:

1. Click **Configure** from the menu bar, then **Services & Workstations**.

   The **Services and Workstations** List Window opens (in [grid view](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/list-windows/grid-view.md)).
2. **Right click** and select **New\...Workstation**.

   By default the **General** tab displays.
3. Complete the fields as required.

   For further detail see [General tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/general-tab.md).
4. Click the **Event Response** tab, and configure as required.

   For further detail see [Event Response tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/event-response-tab.md).
5. Click the **Alarm Instructions** tab, and configure as required.

   For further detail see [Alarm Instructions tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/alarm-instructions-tab.md).
6. Click each tab in turn to configure a Workstation item:

<details>

<summary>Configuration tab</summary>

1. Click the **Configuration** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-1a02ef82af0114b685fb3acb338a9f35f8329a6e%2Fws_configurationtab.png?alt=media)
2. Enter the host PC name in the **Hostname** field.
3. If required, a Door's Reader(s) can be used for card reading and assignment by operators of this Workstation. To allow this, select a Door from the **Assign Card Door** drop-down list. You should choose a Door that is physically located near this Workstation.

   **Note:** There are no checks made to ensure there are valid Readers attached to the Door you select; you should make sure of this before selecting the Door.
4. The **Generate Registration Code** button is for Client Authentication purposes. Client Authentication verifies that a Workstation is what it claims to be, using a Client Certificate installed on the Workstation machine. If your site uses Workstation Restrictions the workstation needs to be registered with a registration code.

   Refer to the "Client Authentication Appendix" in the *Command Centre Release Note* for further detail.
5. The **Site Plan Workstation Orientation** option allows site plans to be orientated to the workstation operator’s seated position.

   If you want to rotate the site plan, enter the appropriate number between 0 and 359 degrees.

   **Notes:**

   * Site Plans rotate anti-clockwise.
   * Site Plan rotation cannot be configured for legacy Site Plans (Site Plans created in Configuration Client).
6. Check the **Disable Exit from Configuration Client** checkbox if you want operators to be unable to exit from this Workstation, to avoid accidental closure of it.

   **Note:** This feature only applies to the Configuration Client and NOT Command Centre Client.

   Checking the **Disable Exit from Configuration Client** checkbox disables:

   * the **Exit** button on the **File** menu bar,
   * the ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-d30a140cb8208828297ae7f96a30bc664512c0b2%2Fclosebutton.png?alt=media) button in the top right-hand corner, and
   * Close < **Alt** + **F4** >

</details>

<details>

<summary>Icons tab</summary>

Click the **Icons** tab if you want to change the Icon Set for this Workstation.

For further details regarding the **Icons** tab, see [Icons](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/server-properties/icons.md).

</details>

<details>

<summary>Restrictions tab</summary>

1. Click the **Restrictions** tab.

   **Note:** This tab will only appear if configured to do so via the Server Properties (on the **Operator Defaults** tab).

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-c2771610ab29653ecf5771c9bd6baf75b22f7598%2Fws_wsrestrictiontab.png?alt=media)
2. Do you want to specify which Operator Groups this workstation is restricted to?

   * If **no**, go to Step 6.
   * If **yes**, tick the **Restrict this workstation to these operator groups** checkbox.

   The main grid becomes enabled.
3. Click **Manage** from the menu bar, then **Operator Groups**.

   The **Operator Group** List Window opens.
4. Select those Operator Groups you want the Workstation to be restricted to.

   Drag and drop them into the **Restrictions** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-81d6322772b9609b20746244c14825dc41def208%2Fogintoworkstation.png?alt=media)

   **Notes:**

   * There must be at least one Operator Group assigned when restricting privileges to a workstation. If you try to save the workstation without assigning any Operator Group(s) an error message will display.
   * If you want to remove an Operator Group from the grid, the **Restrict this workstation to these operator groups** checkbox must remain checked.
5. Close the **Operator Groups** List Window.
6. Do you want this workstation to automatically log off after a specified period of inactivity?

   <table><thead><tr><th width="92">If...</th><th>then...</th></tr></thead><tbody><tr><td>yes</td><td>tick the <strong>Invoke automatic logoff</strong> checkbox and indicate the period of inactivity in the Time Box.<br><br><strong>Note:</strong> An automatic logoff time specified here for this workstation will override any automatic logoff time configured for the entire system, via the Server Properties (on the <strong>Operator Defaults</strong> tab).</td></tr><tr><td>no</td><td>go to Step 7.<br><br><strong>Note:</strong> By leaving the automatic logoff time as disabled, the workstation's automatic logoff time will be the same as the Server's value, (i.e on the <strong>Operator Defaults</strong> tab of the Server Properties).</td></tr></tbody></table>

</details>

7. Click the **Custom Fields** tab if you want to add and assign a custom field value to this Access Zone.

   For further details regarding the **Custom Fields** tab, see [Custom Fields](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/server-properties/custom-fields.md).
8. Click the **Notes** tab if you want to add a note(s) about this Access Zone.

   For further details regarding the **Notes** tab, see [Notes](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/server-properties/notes.md).
9. Click **OK** to exit and save your changes.

   Click **Cancel** to exit without saving your changes.

   Click **Apply** to save your changes and stay in this window.

### Result

A new Workstation Item has been created.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/services-and-workstations/creating-a-new-workstation-item.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.