> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/configuring-hbus-terminals/hbus-terminal-overriding-the-alarm-zone-state-to-armed.md).

# HBUS Terminal: Overriding the Alarm Zone state to armed

### Introduction

If the terminal or HBUS Contact Card Reader has been assigned as the Reader for a Door, the following procedure can be used to arm the Door's Access Zone Alarm Zone.

**Note:** You must have the ‘Change to the Armed state’ Alarm Zone privilege for the Alarm Zone. Refer to [Setting up Access Groups](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-management/access-groups/setting-up-access-groups.md).

### Method 1:

1. Press the **Arm** key.

   **Note:** If the terminal is assigned as the Reader for an Elevator Car, the **Arm** key is not displayed; hence it cannot be used to override the Alarm Zones associated with the Elevator Car’s Access Zones.
2. Log on to the terminal.

   **Note:** The credentials required to log on to a terminal are configured on the **Welcome Screen** tab of the terminal item. By default, the first logon credential is ‘Card’. By default, the second logon credential is ‘PIN’.

   If logon is successful, the message *"The system is armed"* and the Armed icon displays on the terminal.

### Method 2:

Present your card twice, (known as a ‘double card override’) at the terminal.

If arming is successful, the message *"The system is armed"* and the Armed icon displays.

**Notes:**

* To use this feature, ‘Double card overrides’ must be set to ‘Arm alarm zone’ on the **Advanced** tab of the terminal item.
* If the terminal is assigned as the Reader for an Elevator Car, it is recommended that double card overrides not be configured, because of the potential to accidentally override multiple Alarm Zones.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/configuring-hbus-terminals/hbus-terminal-overriding-the-alarm-zone-state-to-armed.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.