> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/configuring-an-hbus-quickswitch-board.md).

# Configuring an HBUS QuickSwitch Board

### Introduction

The Gallagher QuickSwitch ME1502 extends the connectivity of the Gallagher Controller via the HBUS communications protocol. It enables connectivity for 8 inputs and 4 outputs, that match the footprint and terminal location of common third-party control panels.

***

### Configuration

To configure an HBUS QuickSwitch ME1502 Board, perform the following procedures in Gallagher Configuration Client:

1. Click **Configure** from the menu bar, then **Hardware**.

   The **Hardware** List Window opens (in [tree view](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/list-windows/tree-view.md)).
2. **Right click** and select **New\...HBUS Devices**.
3. Select **HBUS QuickSwitch Board**.

   By default the **General** tab displays.
4. Complete the fields as required.

   For further detail see [General tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/general-tab.md).
5. Click the **Event Response** tab, and configure as required.

   For further detail see [Event Response tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/event-response-tab.md).
6. Click the **Alarm Instructions** tab, and configure as required.

   For further detail see [Alarm Instructions tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/alarm-instructions-tab.md).
7. Click each tab in turn and configure the reader properties as required:

<details>

<summary>Status and Overrides tab</summary>

1. Click the **Status and Overriddes** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-466089de1abc966b32ddc1ba3eda4ddbcf4b04ae%2Fquickswitch_status%26overridestab.png?alt=media)

   To prevent continuous tamper alarms, tick the **Disable Tamper** checkbox.

   **Notes:**

   * The battery and power status does not display on this tab.
   * This device does not support timed overrides. All overrides are immediate and persist until specifically cancelled by an operator.
2. To perform an override, click within the **Override** field and select the required override action from the drop-down list, then click the **Override Now** button.

   For a description on each of the override actions that can be performed refer to [Performing Overrides](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-monitoring/status-and-overrides/performing-overrides.md).

</details>

<details>

<summary>Connections tab</summary>

1. Click the **Connections** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-5bad0ee5f0faaf428ca422ccfdb39816e30301c1%2Fquickswitch_connectionstab.png?alt=media)
2. Select the Controller you want to assign this QuickSwitch Board to, from the **Controller** drop-down list.

   **Note:** QuickSwitch Boards can be created via the **HBUS Devices** tab of a Controller. In that case the **Controller** field would be pre-populated with that Controller name. Refer to [Configuring HBUS Devices](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/configuring-hbus-devices.md).
3. Enter the HBUS serial number (10 character hexadecimal string) into the **HBUS Serial Number** field. This serial number is located on the board sticker.

   **Note:** The HBUS serial number is optional, however the board will be considered as not properly configured unless one is entered.
4. If you click the **Apply** button, software version numbers display.

   The **Configured Version** is the version of the device software in the configured Controller FTS file, (i.e. **not** the version of the Controller software).

   The **Current Version** is the version of software as last reported by the board itself.
5. Select the appropriate hardware variant, from the **Hardware Variant** drop-down list.

   **Notes:**

   * If you select either *ME16IN* or *LN-16 IN*, the **Outputs** tab will disappear. Likewise, if you select either *ME16OUT* or *LN-16 OUT*, the **Inputs** tab will disappear.
   * 'Bad Unit' type alarms may occur if the hardware variant attached to the Controller does not match to the hardware variant selected.

</details>

<details>

<summary>Inputs tab</summary>

1. Click the **Inputs** tab if displayed.

   **Note:** The appearance of this screen may differ depending on the hardware variant selected on the **Connections** tab, (e.g. If "AMD50-2D" was selected, there will only be 4 Inputs available).

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-5cd11275b68dd20c226d31bd6bec020f02126615%2Fquickswitch_inputstab.png?alt=media)
2. Assign each Input to the correct address. For details on how to create an Input, refer to [Creating Inputs and Outputs](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/creating-inputs-and-outputs.md).
3. Click the **EOL Resistors** tab.

   This screen allows you to define the wiring and resistance values used on inputs that are connected to this device. Refer to [Configuring EOL Resistors for devices](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/configuring-eol-resistors-for-devices.md).

</details>

<details>

<summary>Outputs tab</summary>

1. Click the **Outputs** tab if displayed.

   **Note:** The appearance of this screen will differ depending on the hardware variant selected on the **Connections** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-a4759a63c6e92fd609f43c8540958b7a57f12878%2Fquickswitch_outputstab.png?alt=media)
2. Assign each Output to the correct address. For details on how to create an Output, refer to [Creating Inputs and Outputs](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/creating-inputs-and-outputs.md).

</details>

8. Click the **Cameras** tab if you want to associate a DVR Camera(s) with this HBUS QuickSwitch Board.

   For further details see [Cameras tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/cameras-tab.md).
9. Click the **Icons** tab if you want to change the Icon Set for this HBUS QuickSwitch Board.

   For further details regarding the **Icons** tab, see [Icons](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/server-properties/icons.md).
10. Click the **Custom Fields** tab if you want to add and assign a custom field value to this HBUS QuickSwitch Board.

    For further details regarding the **Custom Fields** tab, see [Custom Fields](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/server-properties/custom-fields.md).
11. Click the **Notes** tab if you want to add a note(s) about this HBUS QuickSwitch Board.

    For further details regarding the **Notes** tab, see [Notes](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/server-properties/notes.md).
12. Click **OK** to exit and save your changes.

    Click **Cancel** to exit without saving your changes.

    Click **Apply** to save your changes and stay in this window.

### Result

An HBUS QuickSwitch ME1502 Board has been configured, assigned to a Controller, and is ready for use.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/hardware/configuring-an-hbus-quickswitch-board.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.