> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/licensable-features/piv-card-support/open-supervised-device-protocol-osdp-veridt-stealth-piv-readers/assigning-an-osdp-veridt-stealth-piv-reader-to-a-gallagher-piv-controller-6000.md).

# Assigning an OSDP Veridt Stealth PIV Reader to a Gallagher PIV Controller 6000

### Introduction

This procedure describes how to assign an Open Supervised Device Protocol (OSDP) Veridt Stealth PIV Reader to a Gallagher PIV Controller 6000.

**Note:** When a Verdit Reader is connected to a non-PIV Controller and a PIV card is presented, a *"PIV Controller required for this transaction type"* event is generated in Command Centre.

### Procedure

1. Click **Configure** from the menu bar, then **Hardware**.

   The **Hardware** List Window opens (in [tree view](https://help.security.gallagher.com/knowledge-hub/configuration-client/glossary-of-terms.md#tree-view)).
2. Highlight the Controller 6000 you want to assign the new OSDP Veridt Stealth PIV Reader to.
3. **Right click** and select **Properties.**

   By default the **General** tab displays.
4. Click the **Setup** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-41026268edbbbb6eca082f4c9274f9f287843d4a%2Fosdp_controller6000setuptab.png?alt=media)

   In the Hardware section of this screen, select the 'OSDP' option from the **RS-485 Bus 1** and/or **RS-485 Bus 2** drop-down lists as appropriate.

   Depending on which RS-485 Bus option(s) you selected 'OSDP' for, an **OSDP Devices** and/or **OSDP Devices 2** tab appears, allowing you to add OSDP Readers to the Bus port on this Controller.

   **Note:** The recommendation is to use just one OSDP Reader per Bus port.
5. Click the **OSDP Devices** tab.
6. From the **Hardware** List Window, select the OSDP Veridt Stealth PIV Reader(s) attached to this Bus. Drag and drop each reader into the grid on the **OSDP Devices** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-88150cdfa5aa8cec5e42861c6c10148cb150053a%2Fveridtstealthpiv_osdp_controller6000_osdpdevicestab.png?alt=media)
7. Pair the item with the device by selecting the appropriate reader from the grid and entering the address into the **Configured Address** field below. (Address Range = 0 - 126)
8. If you want to change the device address, select the appropriate reader from the grid and enter an address into the **Device Address** field below. Click the **Change Address** button to push the configuration. (Address Range = 0 - 126)

   **Notes:**

   * Address 1 should not be used as it will not work with the Veridt reader, and it resets the baud rate when power cycled.
   * The Change Device Address controls will be disabled if the selected device's status is offline, unknown or unconfigured.
9. If you want to change the **OSDP Bus Baudrate** for communication between the reader and the Controller, select the appropriate baudrate from the drop-down list.

   **Note:** The default baud rate for newly created Controllers will be "115200", but for existing Controllers it will remain as "9600". We recommend "115200" is used for better performance. When reader baudrate is different to Controller OSDP baudrate, the reader will remain offline.
10. Click **OK** to exit and save your changes.

    Click **Cancel** to exit without saving your changes.

    Click **Apply** to save your changes and stay in this window.

### Result

An OSDP Veridt Stealth PIV Reader has been created and it has been assigned to a Gallagher Controller 6000. As a result, the following occurs:

* the OSDP Veridt Stealth PIV Reader will display within the Hardware List Window.
* on the **Connections** tab of the OSDP Veridt Stealth PIV Reader, the Gallagher Controller 6000 name will appear in the **Connected to** field.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/licensable-features/piv-card-support/open-supervised-device-protocol-osdp-veridt-stealth-piv-readers/assigning-an-osdp-veridt-stealth-piv-reader-to-a-gallagher-piv-controller-6000.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.