> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/licensable-features/perimeter-fence-controllers/using-hvplus-mode.md).

# Using HVplus mode

### Introduction

HVplus mode is only available on the F41 and F42 Fence Controllers, and the F61 and F62 Fence Controllers (excluding the EN variants). HVplus mode is enabled by default (the **Enable HVplus Mode** checkbox is checked on the **Advanced** tab in the Fence Controller’s properties).

HVplus mode is triggered when either Fence Zone (armed in High Voltage mode) drops below the configured High Voltage low Fence Alert threshold. The move to HVplus mode occurs after a single pulse below the configured threshold.

HVplus mode increases the high voltage on both Fence Zones to approximately 10 kV (load dependent) for a period of 20 minutes.

**Notes:**

* Only Fence Zones armed in High Voltage mode can transition to HVplus mode.
* The stated time of 20 minutes remains, even if the fence voltage returns to above the High Voltage low Fence Alert threshold.
* After an HVplus escalation, the fence voltage must return to above the High Voltage low Fence Alert threshold, then drop to below the High Voltage low Fence Alert threshold to trigger another HVplus escalation.
* The Fence Controller will enter HVplus mode at 100% power (10 kV), regardless of the High Voltage Power Level, (e.g. 50%) configured on the **Advanced** tab in the Fence Controller’s properties.
* To exit HVplus mode, both Fence Zones must be disarmed or changed to Low Feel mode.

### HVplus indications

* When the Fence Controller enters HVplus mode, the event "HVplus escalation has occurred" is raised in Command Centre.
* When a Fence Zone enters HVplus mode, the event "\[Fence Zone name] – HVplus" is raised in Command Centre.
* Indications that a Fence Zone is in HVplus mode is shown on a terminal.
* When a Fence Zone is in HVplus mode, the Fence Zone icon (in Command Centre) changes to indicate HVplus mode and the HV icon (located on the Fence Controller cover) for the applicable Fence Zone flashes orange.

### Synchronisation

* If the Fence Controller has a synchronization loss active alarm it will still transition to HVplus mode, if the trigger condition occurs.
* HVplus mode is not persisted across synchronised Fence Controllers.

### Temperature management

* If the temperature measured within the Fence Controller unit is less than 72 0C (162 0F) the Fence Controller will transition to HVplus mode, if the trigger condition occurs.
* If the temperature measured within the Fence Controller unit is greater than 72 0C (162 0F) the Fence Controller will not transition to HVplus mode, if the trigger condition occurs. If an HVplus escalation is currently in progress, it is allowed to complete normally.

### When powered by the battery

* If an HVplus escalation condition occurs while the Fence Controller is running on the battery (mains failure has occurred) the Fence Controller will still enter HVplus mode.
* If the Fence Controller enters Stop mode from HVplus mode, the HVplus escalation is cancelled. Once pulsing resumes, it is in High Voltage mode (assuming the unit has remained armed in High Voltage mode throughout).

### Service mode

* If the Fence Controller is in Service mode it will still transition to HVplus mode, if the trigger condition occurs.
* If the Fence Controller is in Service mode and HVplus mode, then both Fence Zones are disarmed or placed in Low Feel mode, the Fence Controller will exit HVplus mode.
* If the Fence Controller is in HVplus mode and Service mode is entered or exited, the Fence Controller will exit HVplus mode.

### Moving from Low Feel mode to HVplus mode

A Macro can be used to override a Fence Zone into High Voltage mode. For example, if a Fence Zone which is armed in Low Feel mode generates an event, the event can be used to drive an Action Plan that has the Macro assigned to override the Fence Zone into High Voltage mode. If fence voltage drops below the configured High Voltage low Fence Alert threshold when in High Voltage mode, the Fence Zone will enter HVplus mode.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/licensable-features/perimeter-fence-controllers/using-hvplus-mode.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.