> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/licensable-features/perimeter-fence-controllers/creating-a-fence-zone.md).

# Creating a Fence Zone

### Introduction

A Fence Zone is a section of perimeter fence (up to 300m length) which is assigned to a Fence Controller in Command Centre. Fence Zones can only be associated with one Alarm Zone, however each Alarm Zone can be associated with any number of Fence Zones belonging to any number of Fence Controllers.

This procedure describes how to create a Fence Zone in Command Centre.

***

### Before you begin

Before you begin this procedure, you need to be in the same or parent Division of the Command Centre items mentioned, and have the "Edit Site" operator privilege to perform this procedure.

***

### Configuration

To configure a Fence Zone, perform the following procedures in Gallagher Configuration Client:

1. Click **Configure** from the menu bar, then **Hardware**.

   The **Hardware** List Window opens (in [tree view](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/list-windows/tree-view.md)).
2. **Right click** and select **New\...Fence Zone**.

   By default the **General** tab displays.
3. Complete the fields as required.

   For further detail see [General tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/general-tab.md).
4. Click the **Event Response** tab, and configure as required.

   For further detail see [Event Response tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/event-response-tab.md).

   **Important:** Fence Zones are energized in response to the state of the Alarm Zone they are associated with on the **Event Response** tab. Configuring a Fence Zone with an Alarm Zone that is not disarmed could unexpectedly energize the fence.

   **Notes:**

   * Each Fence Zone can only be associated with one Alarm Zone. However, each Alarm Zone can be associated with any number of Fence Zones belonging to any number of Fence Controllers.
   * If a Fence Zone is not associated with an Alarm Zone, the Fence Zone will only arm when overridden and will not log any events.
   * If a Fence Zone is assigned to an F3x, F4x, F5x, F6x or F22 Fence Controller, the Alarm Zone will control the HV/LF mode for this Fence Zone.
5. Click the **Alarm Instructions** tab, and configure as required.

   For further detail see [Alarm Instructions tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/alarm-instructions-tab.md).
6. Click each tab in turn to configure a Fence Zone:

<details>

<summary>Alerts tab</summary>

1. Click the **Alerts** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-65cc0939c6f48055add3670972fcd091b4e86b91%2Ffencezone_alertstab.png?alt=media)
2. Corrosion on the fence can cause the voltage to drop. The **Use Adaptive Thresholds** feature allows voltage alarm thresholds to adapt to their environment and prevent false alarms. Effectively, the Fence Controller will not report alarms that result in a gradual drop in voltage.

   **Note:** This feature will not work on F22 Fence Controllers.

   If required, check the **Use Adaptive Thresholds** checkbox.

   The **Alarm Threshold** and **Adaption Rate** options become enabled.
3. Adjust the **Alarm Threshold** percentage (Range = 0 - 100%) and **Adaption Rate** (Range = '1 - Slowest' to'9 - Fastest') as required.

   **Notes:**

   * An alarm will be generated when the return voltage drops below the adapted threshold. The threshold then adapts to the new level and when it does the alarm will be restored.
   * A Voltage Report run for this Fence Zone can show the adapted threshold compared to the actual voltage. Installers may use this report to confirm that they have the adaptive threshold settings suitably configured, (e.g. if they still get false alarms they can increase the settings).
4. Configure as appropriate.

   <table><thead><tr><th width="126">Field</th><th>Description</th></tr></thead><tbody><tr><td>Fence Warning</td><td><p>When in Low Feel mode, if the Fence Controller reports a value less than the Low Feel low value or greater than the Low Feel high value, for three (default) consecutive pulses, a <strong>Fence Low Feel Warning</strong> is raised (Default = medium priority).</p><p>When in High Voltage mode, if the Fence Controller reports a value less than the High Voltage low value or greater than the High Voltage high value, for three (default) consecutive pulses, a <strong>Fence Warning</strong> is raised (Default = medium priority).</p></td></tr><tr><td>Fence Alert</td><td><p>When in Low Feel mode, if the Fence Controller reports a value less than the Low Feel low value or greater than the Low Feel high value, for a period of three (default) consecutive pulses, a <strong>Fence Low Feel Alarm</strong> is raised (Default = very high priority).</p><p>When in High Voltage mode, if the Fence Controller reports a value less than the High Voltage low value or greater than the High Voltage high value, for a period of three (default) consecutive pulses, a <strong>Fence Alarm</strong> is raised (Default = very high priority).</p></td></tr></tbody></table>

   **Notes:**

   * The **Low Feel low** and **Low Feel high** values are only applicable if the Fence Zone is assigned to an F31, F32, F41, F42 or F22 Fence Controller.
   * The **Low Feel low** value must be less than or equal to the **Low Feel high** value (for both 'Fence Warning' and 'Fence Alert').
   * The **High Voltage low** value must be less than or equal to the **High Voltage high** value (for both 'Fence Warning' and ‘Fence Alert').
   * The Fence Warning **High Voltage high** value must be greater than or equal to 12 kV and the Fence Alert **High Voltage high** value must be 15 kV when the Fence Zone is assigned to an F4X Fence Controller. The increase in values is due to the HVplus functionality of the F4X Fence Controller.
   * If the Fence Zone is assigned to an F4X Fence Controller, the **High Voltage low** values will be automatically increased when HVplus mode is entered:

     If between 0 - 2.0 kV the value is increased 31%.

     If between 2.1 - 6.0 kV the value is increased 32%.

     If between 6.1 - 8.0 kV the value is increased 23%.

     If between 8.1 - 15.0 kV the value is increased 20%.

     Due to the automatic increase in values, a Fence Warning or Fence Alert may occur when the fence voltage is greater than the configured **High Voltage low** value.

     For example, if the configured **High Voltage low** value is 2.0 kV, when HVplus mode is entered, the value is automatically increased 31% to 2.6 kV. Hence a Fence Alert will occur when the voltage drops below 2.6 kV and not below the configured 2.0 kV value.

</details>

<details>

<summary>Reflect Outputs tab</summary>

1. Click the **Reflect Outputs** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-21db21362795cc0a673d7ccc9ba08441fac27bfe%2Ffencezone_reflectoutputstab.png?alt=media)
2. Configure **Outputs** as required (drag and drop).

   Outputs turn on while in the Fence Zone state the outputs are placed in.

</details>

<details>

<summary>Data Logging tab</summary>

1. Click the **Data Logging** tab.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-96216f8079d33dd67bc1d2cd89fea741c87f8097%2Ffencezone_dataloggingtab.png?alt=media)

   This screen allows you to configure voltage logging for the Fence Zone. The events logged due to these settings will be used when a Voltage Report is run for this Fence Zone. Refer to [Creating a Voltage Report](https://help.security.gallagher.com/knowledge-hub/configuration-client/licensable-features/perimeter-fence-controllers/creating-a-voltage-report.md) for the procedure.
2. Configure the Data Log voltage change and/or time interval triggers as required.

</details>

7. Click the **Cameras** tab if you want to associate a DVR Camera(s) with this Fence Zone.

   For further details see [Cameras tab](https://help.security.gallagher.com/knowledge-hub/configuration-client/introduction-to-command-centre/knowing-your-way-around/generic-properties-configuration/cameras-tab.md).
8. Click the **Icons** tab if you want to change the Icon Set for this Fence Zone.

   For further details regarding the **Icons** tab, see [Icons](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/server-properties/icons.md).
9. Click the **Custom Fields** tab if you want to add and assign a custom field value to this Fence Zone.

   For further details regarding the **Custom Fields** tab, see [Custom Fields](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/server-properties/custom-fields.md).
10. Click the **Notes** tab if you want to add a note(s) about this Fence Zone.

    For further details regarding the **Notes** tab, see [Notes](https://help.security.gallagher.com/knowledge-hub/configuration-client/site-installation/server-properties/notes.md).
11. Click **OK** to exit and save your changes.

    Click **Cancel** to exit without saving your changes.

    Click **Apply** to save your changes and stay in this window.

### Result

A Fence Zone has been created.

**Note:** The Fence Zone is assigned to an F31, F32, F41, F42 or F22 Fence Controller. Once assigned to a Fence Controller, the following occurs:

* the Fence Zone will display within the Hardware window as a child of the Fence Controller, and
* on the **Connections** tab of the Fence Zone, the Fence Controller name will appear in the **Connected to** field.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/licensable-features/perimeter-fence-controllers/creating-a-fence-zone.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.