> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/integrated-systems/salto-lock-interface/space-site-configuration/salto-doors-or-esds.md).

# Salto Doors or ESDs

### Introduction

This procedure describes how to create the access control for Doors (wired online, non-wired offline and wireless locks) and offline Energy Saving Devices (ESDs) within the Salto application.

**Note:** Salto Doors and offline ESDs are represented as Salto Door items in Command Centre. Changes made to Salto Door names and descriptions in Command Centre update automatically in Salto without performing an ‘Update Access Points’, when Salto is online or comes online after being offline. Likewise, Salto Doors can be deleted from Command Centre and the deletion occurs automatically in Salto when Salto is online.

### Procedure

1. Select **Access points > Doors**.

   The Doors screen is displayed.
2. Click **Add Door**.

   The Door information screen is displayed.

   ![](https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-9a8ed092159939e63b5e61d4fa84ee395d1e9478%2Fdoor.png?alt=media)
3. Type in the name of the Door or offline ESD in the **Name** field.

   **Notes:**

   * Doors and offline ESDs are represented as Salto Door items in Command Centre, so it is recommended that you clearly identify this item, (e.g. Door 1 wired). Characters '@' and '(X)' should not be used in the name field.
   * The Salto Door or offline ESD name must match the Command Centre name. If the names do not match, card events will not show the source and the next 'Update Access Points' will cause the Command Centre item to be deleted.
4. Type in a description for the Door or offline ESD in the **Description** field, if required.

   **Note:** If a description is entered, it will not be replicated to Command Centre during an 'Update Access Points'.
5. Check that the remainder of the fields contain the required set up.

   <table><thead><tr><th width="180">Field / Checkbox</th><th>Description</th></tr></thead><tbody><tr><td>Connection Type</td><td><p>This drop-down provides a list of connection types for the door. The default option is Offline. When you select any other (wireless) connection types from the <strong>Connection Type</strong> drop-down list, a <strong>Configure</strong> button is displayed on the Door information screen. Additional panels are also displayed on the Door information screen, depending on the connection type selected. Connection types are: Offline, Online IP (CU5000), Online IP (CU4200), Online RFnet, Online BLUEnet and Online BAS.</p><p><strong>Note:</strong> If you select "Online BLUEnet" as the connection type, an additional <strong>Enable key update</strong> option appears which only applies to BLE locks/readers. Setting this configures the door as an update point.<br><img src="https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-8a67dd983e1a6e7205c289b65111042489d05fdb%2Fsalto_enablekeyupdateoption.png?alt=media" alt=""></p></td></tr><tr><td>Open time</td><td>This field determines the time passed from the moment access is granted, until the electronic system locks it again.<br><strong>Salto Default</strong> = 6<br><strong>Command Centre Equivalent</strong> = Door unlock time<br><strong>Command Centre Default</strong> = 5</td></tr><tr><td>Increased open time</td><td>Defines a longer opening time. This option is designed for disabled or ‘hands full’ users. The default time value is 20 seconds. The value can be increased or decreased in the range 0 to 255 seconds. You must enable this option in the user’s profile. If extended access time is used in Command Centre, it is then used in Salto as the increased open time.<br><strong>Salto Default</strong> = 20<br><strong>Command Centre Equivalent</strong> = Extended access time<br><strong>Command Centre Default</strong> = 25</td></tr><tr><td>Audit on keys</td><td><p>Allows monitoring of when and where keys are used. You must enable this feature on both the access point and the user’s key. When this option is selected, the door is enabled to write or stamp the audit on the key as long as the key’s memory is not full.</p><p><strong>Salto Default</strong> = Off (should be changed to ON for non-wired offline locks)</p><p><strong>Command Centre Equivalent</strong> = Automatic in Command Centre</p></td></tr><tr><td>Audit inside handle opening</td><td>Allows monitoring of when a user exits a door. For RF doors, this data is automatically transferred and displayed in the audit trail.</td></tr><tr><td>Admit expired keys</td><td>The door can be configured to admit cards already expired for a certain amount of days.</td></tr><tr><td>Open mode *</td><td>This determines the electronic locks working mode. You can select one from the drop-down list provided.<br><strong>Salto Default</strong> = Standard (can be changed if needed)<br><strong>Command Centre Equivalent</strong> = Secure - Card and no PIN<br><strong>Command Centre Default</strong> = Secure - Card and No PIN</td></tr><tr><td>Calendar</td><td>This drop-down provides a list of the calendar configurations that have been created. This is useful when there are doors in different geographical areas with different calendar configurations.<br><strong>Salto Default</strong> = Calendar000<br><strong>Command Centre Equivalent</strong> = Access Mode in Access Zone<br><strong>Command Centre Default</strong> = User selected</td></tr><tr><td>Enable antipassback</td><td>This feature is not supported in Command Centre.</td></tr></tbody></table>

   \* The options available in the **Open mode** drop-down list are described below, along with the nearest Command Centre equivalent:

   <table><thead><tr><th width="180">Mode</th><th>Description</th></tr></thead><tbody><tr><td>Standard</td><td><p>The lock will only open if you use an authorised key card, within its allowed Timezones.</p><p><strong>Command Centre Equivalent</strong> = Secure</p></td></tr><tr><td>Office</td><td><p>The door is unlocked. Access does not require an authorised key card whilst the door is in this mode, however:</p><p>when using SOLID spindles on Salto door escutcheons, (e.g. Standard European Mortise locks) enabling this mode requires an authorised key card to be presented whilst holding down the INTERNAL door handle. To disable office mode, repeat this procedure.</p><p>when using SPLIT spindles on Salto door escutcheons (e.g. Australian ANSI Mortise locks), enabling this mode requires an authorised key card to be presented whilst holding down the EXTERNAL door handle. To disable office mode, repeat this procedure.</p><p><strong>Command Centre Equivalent</strong> = Override to free</p></td></tr><tr><td>Timed office</td><td>This is the same as "Office" mode (above), except that it can only be enabled within specified Time periods. Note that the lock will automatically revert to "Standard" mode at the end of the Timed period.<br>When this option is selected, a new <strong>Timed periods</strong> field appears with a default value of “Time period 001”. You need to select one of the opening periods available from the drop-down list, and then define a period using the <strong>Timed</strong> <strong>Periods</strong> tool (from the main Salto menu bar).<br><img src="https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-b7a2b9473f2a8eafadbe7bae08fd01a70923cb8c%2Ftimedperiods.png?alt=media" alt=""><br><strong>Command Centre Equivalent</strong> = Override to free within time-frame</td></tr><tr><td>Automatic opening</td><td><p>This is similar to "Timed office" mode (above), but the door can switch to and from office mode automatically without any manual user operation. In this mode, it is also necessary to set a time period (defined with the <strong>Timed Periods</strong> tool).</p><p><strong>Command Centre Equivalent</strong> = Scheduled change, (i.e. when a door is scheduled to be secure sometimes and free at others).</p></td></tr><tr><td>Toggle</td><td><p>In this mode, presenting an authorised key card will set the door in "Office" mode, without needing to hold down the inner handle. The next authorised key card presented will cancel "Office" mode. It continues "toggling" the office setting on presentation of each authorised key card.</p><p><strong>Command Centre Equivalent</strong> = Free/Secure Double card override</p></td></tr><tr><td>Timed toggle</td><td><p>This mode works in the same way as "Toggle" mode (above), except that you can only toggle the door within a set 'Timed Period'.</p><p><strong>Command Centre Equivalent</strong> = No equivalent</p></td></tr><tr><td>Automatic opening + office</td><td><p>This mode is the same as "Automatic opening" mode, except that out of the opening periods, the escutcheon can be left in "Office" mode by a user with this attribute enabled.</p><p><strong>Command Centre Equivalent</strong> = Override to free within time-frame</p></td></tr><tr><td>Keypad only</td><td>Supported in Command Centre. A lock can be opened at any time by entering a valid code on the keypad. The keypad code must contain between one and eight digits and is the same for every user. When you select the <strong>Keypad only</strong> option from the <strong>Open mode</strong> drop-down list, a keypad code field is displayed in which you can define the code. The lock can also be opened with a valid key. A "Code only access granted entry at [Salto Door]" event is raised in Command Centre.</td></tr><tr><td>Timed keypad</td><td>Not supported in Command Centre.</td></tr><tr><td>Key + PIN</td><td>Not supported in Command Centre.</td></tr><tr><td>Timed Key + PIN</td><td>Not supported in Command Centre.</td></tr><tr><td>Automatic opening + Office</td><td>This mode works in the same way as the Automatic opening mode. However, outside of the timed period, the lock reverts to Office mode rather than Standard mode.</td></tr><tr><td>Automatic opening + Toggle</td><td>This mode is the same as Automatic + Office mode except that outside of the timed period the lock reverts to the Toggle mode.</td></tr><tr><td>Automatic changes</td><td>This ‘mode’ acts as an indication that the lock will work with a mixture of modes during certain time periods throughout the day. The combination of modes is defined in an automatic changes entry, for example, Automatic change#001. You can select an automatic changes entry using the drop-down list in the <strong>Automatic changes</strong> field.</td></tr></tbody></table>
6. Click **Save**.

### What happens next?

You will now need to associate a Salto zone with the Door or offline ESD. Command Centre Cardholder access to the Salto zone will provide access to the Door or offline ESD. Salto guest access to the Salto zone will provide access to the Door or offline ESD.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/integrated-systems/salto-lock-interface/space-site-configuration/salto-doors-or-esds.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.