> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/integrated-systems/morpho-biometric-integration/installing-morphoaccess-readers/supported-morphoaccess-readers.md).

# Supported MorphoAccess Readers

The following MorphoAccess readers and associated firmware versions are supported.

**Important Notes:**

* Gallagher recommends the latest release firmware version for supported devices.
* For site security, it is recommended that the default passwords on all Biometric readers be changed after readers have been configured.
* Changing default reader settings other than those mentioned in this document may adversely impact reader functionality.
* Morpho Biometric Readers have their time synchronised with the Command Centre server daily. By default, it synchronises at 3:30 am.
* IDEMIA ceased support for the Legacy (MA2G) communication protocol for all devices as of January 2022. Consequently, we no longer support MA2G.
* Upgrading to Command Centre v9.30 will not be possible if you have IDEMIA Legacy (MA2G) devices configured.
* All devices shipped from IDEMIA since October 2020 have been preloaded with MA5G firmware.
* IDEMIA recommend keeping device firmware up to date,as they regularly make improvements that protect against potential cyber attacks.
* Device firmware can be downloaded from the IDEMIA Biometric Devices Portal. See the tables below for a summary of supported and unsupported IDEMIA devices and communication protocols, plus recommendations.

<details>

<summary>Supported IDEMIA Devices and Firmware Versions</summary>

<table><thead><tr><th>IDEMIA Device</th><th>Communication protocol</th><th>Recommendation</th><th>Most recent firmware version available</th></tr></thead><tbody><tr><td>MA Sigma Light Series,<br>MA Sigma Wide,<br>MA Sigma Extreme</td><td><strong>MA5G</strong> (<strong>MA2G</strong> unsupported from Command Centre v9.30)</td><td>Update firmware to Native (MA5G), as required</td><td>Latest Firmware available</td></tr><tr><td>MA Wave XP</td><td rowspan="5"><strong>MA5G</strong> only</td><td rowspan="5">Update firmware to latest version, as required</td><td>Latest Firmware available</td></tr><tr><td>MA Wave XP2</td><td>Latest Firmware available</td></tr><tr><td>MA Wave SP</td><td>Latest Firmware available</td></tr><tr><td>MA VisionPass</td><td>Latest Firmware available</td></tr><tr><td>MA VisionPass SP with Fingerscan</td><td>Latest Firmware available</td></tr><tr><td>Sigma Touch Go,<br>Sigma Touch Pro</td><td></td><td></td><td>Latest Firmware available</td></tr></tbody></table>

Click link below to download Morpho Reader Firmware files:

<https://biometricdevices.idemia.com/s/products>

</details>

<details>

<summary>Unsupported EOL IDEMIA Devices</summary>

These devices will not be supported from Command Centre v9.30:

<table><thead><tr><th width="263">IDEMIA Device</th><th width="291">IDEMIA End of Life (EOL) Date</th><th>Recommendations</th></tr></thead><tbody><tr><td>MA100 Series</td><td>January 2013</td><td>Replace with MA Sigma Light Series</td></tr><tr><td>MAJ Series</td><td>February 2016</td><td>Replace with MA Sigma Light Series</td></tr><tr><td>MA500 Series</td><td>July 2016</td><td>Replace with MA Sigma Wide</td></tr><tr><td>Finger Vein Print - VP</td><td>June 2021</td><td>Replace with MA Wave</td></tr></tbody></table>

</details>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/integrated-systems/morpho-biometric-integration/installing-morphoaccess-readers/supported-morphoaccess-readers.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.