> For the complete documentation index, see [llms.txt](https://help.security.gallagher.com/knowledge-hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://help.security.gallagher.com/knowledge-hub/configuration-client/integrated-systems/aperio-integration/aperio-communication-hubs/aperio-ah20-1-1-wiegand-hubs.md).

# Aperio AH20 1:1 Wiegand Hubs

As an entry level installation, an Aperio Wireless Lock may be connected to a Gallagher Controller through either an "Aperio AH20 Advance Wiegand" Hub or an "Aperio AH20 Standard" Hub. Each Aperio Wiegand Hub can only support one Aperio wireless lock or reader.

### AH20 Standard Wiegand Hubs

When installed in this configuration, the Aperio wireless lock will only be able to offer basic functionality at the same level as other standard Wiegand third party readers. Gallagher Command Centre will not be able to distinguish an Aperio Wiegand Hub/Lock configuration from other standard wired Wiegand readers.

**Note:** AH20 Standard Wiegand Hubs do not support battery monitoring, DPS (Door Position Sensor), RX (Request-to-exit), or tamper.

<table data-header-hidden><thead><tr><th align="center" valign="top"></th><th align="center" valign="top"></th></tr></thead><tbody><tr><td align="center" valign="top"><em>AH20 Gen5 Wiegand connectors</em><br><img src="https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-ecdb9a60e45eb11297459af2910ca2fd591ff8a7%2Fah20gen5connectors.png?alt=media" alt=""></td><td align="center" valign="top"><em>AH20 Standard Wiegand connectors</em><br><img src="https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-5f60856c8a032818746987884c7af72cf3e92396%2Fah20stdwiegandconnectors.png?alt=media" alt=""></td></tr></tbody></table>

The AH20 communication hub has four Wiegand signals plus ground. The following table describes the purpose and connection of these signals:

<table><thead><tr><th width="123">Hub Connector</th><th width="149">Descritpion</th><th>Connected to</th></tr></thead><tbody><tr><td>DATA 0</td><td>Wiegand Data 0 signal</td><td>Output from AH20 hub that connects to Gallagher Wiegand device DATA0.</td></tr><tr><td>DATA 1</td><td>Wiegand Data 1 signal</td><td>Output from AH20 hub that connects to Gallagher device DATA1.</td></tr><tr><td>GREEN</td><td>Wiegand Green LED signal</td><td>Input to AH20 hub, that connects to Gallagher device Out 1, used for access decision from the Gallagher Controller.</td></tr><tr><td>RED</td><td>Wiegand Red LED signal</td><td>Input to AH20 hub, that connects to Gallagher device Out 2, used for access decision from the Gallagher Controller. (Alternatively, leave unconnected if signal is selected not to be used by DIP switch 1.)</td></tr><tr><td>GND</td><td>Ground</td><td>Signal ground needs to be common with the Gallagher device and the power supply GND.</td></tr><tr><td>8-24 VDC</td><td>Positive voltage</td><td>Power supply positive. Power supply input, 8-24 V DC. The power supply shall be a Limited Power Source (LPS) according to EN 60950-1. The power supply shall be 3A over current protected. Wire requirements 16-22 AWG.</td></tr></tbody></table>

### AH20 Advanced Wiegand Hubs

The "AH20 Advanced Wiegand" Hub provides for additional relays at the Wiegand connection point to facilitate outputs from the Aperio wireless lock. Such outputs could be used to monitor the door position sensor, key override, request to exit, or any other sensor that may be present on an Aperio lock.

<table data-header-hidden><thead><tr><th align="center" valign="top"></th><th align="center" valign="top"></th></tr></thead><tbody><tr><td align="center" valign="top"><em>AH20 Gen5 Advanced Wiegand connectors</em><br><img src="https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-edaeb298a6dd40a494f725b2d4cd7d6bac061d5f%2Fah20gen5advhubs_1.png?alt=media" alt="" data-size="original"></td><td align="center" valign="top"><em>AH20 Advanced Wiegand connectors</em><br><img src="https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-a5106ab51148a06508864322f1d4c5db3d0741a7%2Fah20advwiegandhubs_1.png?alt=media" alt="" data-size="original"></td></tr></tbody></table>

<table data-header-hidden><thead><tr><th align="center" valign="top"></th><th align="center" valign="top"></th></tr></thead><tbody><tr><td align="center" valign="top"><em>AH20 Gen5 Advanced Wiegand connectors</em><br><img src="https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-7076d7a630c96a7cd68f8f9c9a6ac3a62db690a3%2Fah20gen5advhubs_2.png?alt=media" alt="" data-size="original"></td><td align="center" valign="top"><em>AH20 Advanced Wiegand</em><br><em>connectors</em><br><img src="https://3000903572-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FfCvaxj3suxNBzdwQndVT%2Fuploads%2Fgit-blob-c80aa22ee08dfcd9d6b7dbdc854f4c4811bcca30%2Fah20advwiegandhubs_2.png?alt=media" alt="" data-size="original"></td></tr></tbody></table>

<table><thead><tr><th width="148">Relays</th><th>Description</th></tr></thead><tbody><tr><td>Relay 1/K500</td><td>DPS (Door Position)</td></tr><tr><td>Relay 2/K501</td><td>RX (Request to exit)</td></tr><tr><td>Relay 3/K502</td><td>Battery Alarm Output</td></tr><tr><td>Relay 4/K503</td><td>Tamper Alarm Output/Lock Jammed</td></tr></tbody></table>

<table><thead><tr><th width="147">Relay Contacts</th><th>Description</th></tr></thead><tbody><tr><td>NCL</td><td>Normally Closed</td></tr><tr><td>COM</td><td>Common</td></tr><tr><td>NOP</td><td>Normally Open</td></tr></tbody></table>

**Note:** The latest Gen5 Hubs have a tamper switch and 8 DIP switches, as opposed to the original Hubs with 10 DIP switches.

For further details of connections on the AH20 Hubs, refer to *Aperio Hub AH20-AH30 Installation Instructions.pdf*


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://help.security.gallagher.com/knowledge-hub/configuration-client/integrated-systems/aperio-integration/aperio-communication-hubs/aperio-ah20-1-1-wiegand-hubs.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.