8.30 Maintenance Release 3
Enhancements or bugs resolved in this version are as follows.
Important Notes:
Command Centre version numbers comprise a major build version and a minor build version, (e.g. for version vEL8.30.1359, 8.30 is the major build and 1359 is the minor build). Server and workstation major builds must always match, however the minor build on the workstation can be equal to or lower than the server minor build.
This feature is intended to ease the effort required for upgrades by allowing a server only maintenance upgrade. Some maintenance fixes are workstation based and may require a workstation upgrade to resolve an issue. Sites that are using ClickOnce installation of Command Centre and Configuration Client will automatically upgrade the clients.
Example: For this Maintenance Release, sites that are already running Full Release version of v8.30 Command Centre Server, can choose to leave their MSI workstations running Full Release version vEL8.30.1057 if they are not affected by the bugs fixed in “Workstation”. Please refer to the “Fixed In” column in the below table for full details.
Category
Fixed In
Description
Tech Ref
Action Plan
Controller
Command Centre items continue to follow default Action Plan, ignoring assigned custom Action Plan
83652
Cardholder Viewer
Workstation
Improvements to Cardholder search
82577
Clients
Workstation
Workstations failed to logon with ‘The configured server is not trusted by this client’
83601
Command Centre
Server
‘Lock request time out period exceed’ error when saving Cardholder
84584
Command Centre
Server
Duplicate instances of Access Group memberships with same from/until time are sent to the Controller
82858
Command Centre
Server
Exception created due to incomplete card records
82943
Command Centre
Server
Memory leak that impacts monitored items and server performance
81925
Command Centre
Workstation
Command Centre Client crashing due to memory exceptions caused by Automation peers
82699
Command Centre
Workstation
Server creates exception when there are disconnects in DCOM tunnelling
82272
Command Centre Client
Server
Cardholder history not updating on cardholder viewer, due to enforcement of CSN length
83881
Command Centre Client
Workstation
Command Centre Client crashes due to ‘system out of memory exception’
85939
Command Centre Client
Workstation
Controlled Entry Viewer customisation exception when closing a viewer
82872
Command Centre Client
Workstation
Failed logons can result in TCP connections being left behind
85191
Configuration Client
Workstation
Add an additional unlock button to Windows logon Operator configuration
82843
Controller
Server
Controller logging improvements
85679
EDI
Server
EDI not running after upgrading due to custom defined stored procedure
83026
Elevator
Server
Exception created when using OPC with elevator systems
82019
Macros
Server
Exception when alarms are processed using Macro while system alarms are visible in the viewer
82870
Morpho
Server
Fingerprint is not updated on the Morpho reader
82719
Morpho
Server
Prevent exception if biometric communicator could not be created/launched
85015
Multi-Server
Server
Remote Server exception caused by scheduling Macro
84472
Notifications
Server
Enabling Card expiry notification on Card Types produces erroneous notifications
83325
Otis Compass
Server
Mobile Credential does not work with default floor
83854
Server
Command Centre performance degrade when PDF is configured with dates earlier than 01/01/1900
85273
Server
PDF performance improvements
83669
Performance
Server
Controller Service optimisations
84038
Performance
Server
Mobile Access readers incurring significant performance reduction
84959
85212
Performance
Server
Rest API memory leak
85604
Printing
Workstation
Exception created if print preview window is closed while printing
82446
PSTN Dialler
Controller
Support for new PSTSN Dialler component
83210
Site Plan
Workstation
Configuration Client Site Plan Icons may flicker after upgrade
82191
SNMP
Server
Services fail to start after upgrade with large SNMP config
82491
System Upgrade
Server
Command Centre fails to upgrade due to duplicate items in the Bulk change
82367
T2x Readers
Controller
CAC G&D cards are not detected at T21 contact card reader
78114
Test Server
Server
Sites can load production server database on test server based on original serial number without affecting their Mobile Credentials
84330
Last updated